Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
78
e) Check effectiveness of instruction
Figure 58 A diagram of the programming editing operation in programming mode
8.13.5 Command Explanation
Command meaning in laser working status is shown in Table 16
Table 16 command meaning in laser working status
Code (1 Byte)
Parameter1(2 bytes
)
Parameter 2
(
4 bytes
)
Note
1
Stop
none
none
The program end
command. the last
command must be this
command.
2
SPT
0
~
65000
(
MS
)
0
~
65000(W)
Change power to 2 in
time 1
3
SPR
0
~
65000
(
W/MS
)
0
~
65000(W)
Change power to 2 in
power change ratio 1
4
WAIT
1
Wait for sync
signal low level
Null