Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus 1000W
~
2000W laser
17
①
CTRL-INTERFACE: Control interface, this interface is a male DB25 connector and it’s
multi-functional. The end users can set the control mode and input analog control signal
with the interface, as well as get the fault signal from it.
②
RS-232: RS-232 serial port, Provide remote control and alarm information storage for the
laser.
③
SERVICE: The laser switch and security interlocking interface
④
MOD: Modulation input, Bayonet Nut Connector can apply to switch to disable or enable
the laser. The control signal should be able to apply current over 10mA, and the voltage
should be 24V.
⑤
WATER IN/OUT: Water pipe connectors, the inlet and outlet for cooling water to flow in
and return
⑥
AC INPUT: 1000W and 1500W laser match 220VAC,2000W laser match 380VAC.
⑦
ETHERNET: Ethernet interface. Provide remote control and alarm information for the
laser.
4.2 Power Connection
Before connecting the product to AC supply source, you must check up that
the AC supply you will apply is in accordance with the specifications
provided.
One end of the power cord is a plug, insert it into the socket 'AC INPUT' on the rear
panel.1000W and 1500W lasers’ power line consist of three lines, L, N and PE, Connected to the
220VAC. 2000W lasers’ power line is made up of four lines,L1,L2,L3 and PE, Connected to the
380VAC.
受
控
武汉锐科