Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus 1000W
~
2000W laser
24
For better communication stability, recommend to use this interface first.
The steps of Ethernet connection:
a
)
Open the Raycus PC software, click "Session
→
RS232 (or Ethernet)" to make the PC
communicate with the laser, and then click "Tool
→
Laser IP Set" to enter the laser IP
address setting;
b
)
The default password is "1122334455667788". After the verification is passed, read or set
the new laser IP address.
c
)
If you use the Raycus PC software to control the laser, you need to find the folder where the
PC software is located, open the laser configuration file “config.xml”, and write the newly
laser IP address. If you do not use Raycus software, please go to the step 4;
d
)
Configure TCP/IP, select "Use the following IP address", manually assign an IP address,
and the IP address of the PC must be in the same network segment as the laser IP address,
and assign a subnet mask address. The default is 255.255.255.0, click the "OK" button to
confirm the settings and exit.