This alarm occurs, Pin15 and Pin 16 in the ‘CTRL-INTERFACE’ interface has
been connected before the laser is powered on.
Solution:
Please power off and disconnect Pin15 and Pin 16 in the ‘CTRL-INTERFACE’
interface the “LASER” button. Repower and check if the alarm is resolve. If this
alarm continues to occur, please contact Raycus.
InterLock Alarm
Instruction:
Occurs when the InterLock is disconnected.
Solution:
Short the InterLock pins and restart the laser to try. If this error continues to
occur, please contact Raycus.
Current Driver Alarm
Instruction:
Current Driver Alarm, this error occurs when the constant current driver board
inside the laser is abnormal.
Solution:
Restart the laser, If this error continues to occur, please contact Raycus.
Laser Power Alarm
Instruction:
The laser will get this error when it does not emit with correct settings. Power
error occurs only when the laser is emitting.
Solution:
Restart the laser, if this error continues to occur, please contact Raycus.
ACDC1 Alarm
Instruction:
ACDC1 Error, failure of the laser power supply or sudden power failure of the
power supply system may cause an alarm.
Solution:
Check if the input AC voltage is normal. Restart the laser, if this error continues
to occur, please contact Raycus.
T1/T2/T3/T4 Alarm
Instruction:
Low temperature/high temperature alarm of the laser. The sensor in the laser
detects an abnormal temperature inside the laser. A high-temperature /
low-temperature error occurs when the temperature at the monitoring point
exceeds the set upper / lower limit.
Solution:
High temperature alarm, please check if the water-cooling system is normally
working, the water temperature is set correctly, and the water connection is
correct. When the water cooling system works normally and the water
temperature drops below 30°C, restart the laser. If the alarm continues, please
contact Raycus. Low temperature alarm, please check if the actual water
temperature of the water is too low. In addition, a low ambient temperature may
also cause a low temperature alarm when the laser is cold. Please wait until the
water temperature of the water rises above 10°C. If the alarm continues, please
contact Raycus.
Hum Alarm
Instruction:
The laser detects that the current water-cooled plate temperature is lower than
the internal dew point temperature, There is a risk of condensation in the
equipment internal.
Solution:
Stop using the laser immediately, Waiting for ambient temperature to come back
to normal, Repower the laser. If the alarm continues to occur, please contact
Raycus.
In addition to the above, if there are any questions or errors in using of the laser, you can
contact Raycus to get help.