Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus 1000W
~
2000W laser
9
It is recommended to install the laser in an air-conditioned environment so
that the laser can operate under optimal conditions.
Do not expose this product to high humidity
(>
70%
)
Do not expose this product to high temperature
(>
40%
)
Do not let this product work below the ambient dew point
temperature
Table 4 The Constant Dew Point Table
The necessary moistureproof treatment has been done in the design of the
laser, but the influence of too serious condensation cannot be avoided 100%.Since
condensation is an objective physical phenomenon, there are usually two ways to
avoid it:
(
1
)
The water temperature of the water-cooling machine is higher than the
dew point temperature, but it should meet the cooling requirements of the laser.
Therefore, in the corresponding environment, the water temperature of the laser
can only be set in the blue region of the dew-point comparison table, so this
method has certain limitations.
(
2
)
By changing the temperature and humidity of the working environment
of the laser and reducing them through air conditioning, the water-cooling
temperature of the laser can be relaxed and the water temperature can be far away
from the dew-forming temperature.