Wuxi Raycus Fiber Laser Technologies Co., Ltd.
User Guide of Raycus 1000W
~
2000W laser
18
Figure 6: Rear View
(
1
)
CTRL-INTERFACE:
Control interface, this interface is a male DB25
connector and it’s multi-functional. The end users can set the control mode
and input analog control signal with the interface, as well as get the fault
signal from it.
(
2
)
RS-232:
RS-232 serial port, Provide remote control and alarm information
storage for the laser. Raycus provides a matching RS-232 serial
communication cable.
(
3
)
SERVICE
: Provide external functions of the customer.
(
4
)
MOD:
Modulation input, a signal for switching the laser on and off in
remote control modes. The control signal should be able to apply current
over 10mA, and the voltage should be 24V.
(
5
)
WATER IN/OUT
: Water pipe connectors, the inlet and outlet for cooling
water to flow in and return
(
6
)
AC INPUT:
The socket for supply source input that can only be mated
with the plug on the power cord we provided.1000W and 1500W laser
matchs 220VAC,2000W laser matchs 380VAC.
(
7
)
ETHERNET
:Ethernet interface. Provide remote control and alarm
information storage for the laser.