6.5. Set the Power Analog Quantity in REM Mode to Control the Laser Emission
Raycus Laser
Figure 20 REM mode power and laser emission are externally controlled wiring diagram
Operations Steps
a) Turn the knob switch on the rear panel to“ON”
b)Turn the key switch to“REM”
c) Short-circuit pin 8/9 on XP2
d)XP1-A1 connects to 24V, XP1-A6 connects to 24V
e) Connect XP1-A5 to 24V and turn on the guide laser; after checking the optics, connect XP1-A5 to
0V and turn off the guide laser
f)XP1-C1 is connected to 24V, and the main power is turned on (operator can also directly press the
LASER button, or the host computer software clicks the main power “ON”);
g)Waiting for “Ready”;
h)XP1-A2 connects to 24V, and the control board outputs analog and MOD signals
XP1(Hardwiring)
A1(Laser Request)
A6(Analog EN)
A2(Laser EN)
A16(COM)
Power ON
Interlock1
L1
AC POWER
~380VAC
AC INPUT
L2
L3
PE
XP2
(Security Interface)
1
2
8
9
17
18
19
20
Interlock2
XP4(Analog Interface)
Peripheral
Equipment
Analog value(0~ 10V)
Analog GND
MOD+
MOD -