38
Key turning “ON”;
Shortconnect the 8 and 9 pins on the INTERFACE 24 pins (the control board is powered
on);
Open the laser clientware;
Click “the guide laser ON” button to view the guide laser;
Open the AD mode, turn off the external enable, and opening the internal modulation mode
or external modulation mode;
Click ON “the main power ON”;
Waiting “Ready”;
On modulate mode set the frequency, duty cycle, and pulse width;(The laser is determined
by the 15. 16 pin modulation signal and frequency and duty cycle);
Modulation signal (15, and 16-pin) and analog quantities ( 12 and 14 pins) turn on the laser.
4.9 Guide laser control
"Guide laser external control" can be selected in both ON and REM modes.
Guide laser external control
ON
17 pin
Rising edge -- turns on guide laser;
Fallingedge -- turns on guide laser.
OFF
The clientware
:
Red ON -- turns ON guide laser;
Red OFF -- Turns OFF guide laser.
4.10 The Programming Mode (Waveform Editing)
4. 10. 1 The Programming Mode enable method
In the Programming Mode, the laser has the functions of waveform editing, storing and
calling. The Programming Mode can be used in the external modulation mode in both ON and
REM modes.
Note: The Programming Mode function is used in REM mode, only the external modulation
mode can be selected, and the internal modulation mode cannot be selected.