48
5 Alarms and Solutions
5.1 Alarms Display
When the laser establishes communication with the client software, all alarm states of the
laser can be displayed on Raycus clientware, as shown in Figure 41(Download the Raycus
software and software manual, please log in to Raycus official website)
Figure 41 The homepage of the clientware
If any alarm occurs (except for Interlock alarm)when the laser is running, the clientware will
display the alarm that occurs, and the ALARM light (yellow) on the front panel of the laser will
light up, the laser will stop emitting and lock.
When the Interlock is abnormal, the output of Ready signal is low, and the Interlock state is
abnormal in the clientware, but the laser is not locked, and the ALARM light (yellow) is not lit.
The output of Ready signal is on high level when the Interlock is normal.
5.2 Alarm solutions
The instructions and solutions of alarms are as follows: