Trouble Shooting

Step 1: Basics

Check blue LED ‘power on’ light is illuminated on the back of the IP unit. 

If 

Yes

,

•  Ensure power adjust is turned to the maximum level.
•  Ensure  Photocell  is  covered  and  if  necessary  adjust  the  photocell 

sensitivity.

If 

No

,

•  Confirm that the PoE injector unit is fully functioning.

nB: Refer to manufacturer’s guide

•  Check that the cable is fully intact, and not broken or split.

Step 2: Set-up Camera, lens and illumination

Check alignment of lamp
Check camera lens – fully open at night & set correctly. 
Check  model  number  to  RayLED  performance  specification  to 

ensure required distance is achievable.

Step 3: Contact RayLED for further assistance

note down:
• Model, Angle and Wavelength ve any options
• Serial number of illuminator
• Camera make and model
• Lens make and model

Summary of Contents for raymax 25 poe

Page 1: ...ce 2 Adjust vertical angle 3 Tighten all fixings Package Contents 1 Illuminator with Integrated PSU illuminators installation guide MAX 25PoE This installation guide provides instructions for installing the RAYMAX 25 IP series illuminators Version 5 0 Overview RAYMAX 25 IP illuminator Integrated PSU back of illuminator ...

Page 2: ...rained and qualified personnel LED illuminator Standard U Bracket Do not continually stare at lamp 1 5m Install internally only PoE Power adjust P cell adjust Power On Power Indicator Telemetry Control telemetry input requires zero volt latched input non polarity sensitive PoE Input 12V DC 24V AC DC Optional input instead of PoE ...

Page 3: ...ptimum image performance TARGET Tighten all fixings 2 3 Adjust vertical angle Match illumination to camera field of view Camera Light Light x x Light Camera Reduces performance May cause hot spots Best performance Camera InteRnal use only Use wall bracket if you require horizontal adjustment ...

Page 4: ...r Weight Dimensions L x W x D PoE or 12V DC 24AC DC 12W IEEE802 3af Compliant Interface Power classification class 0 CAT5 Cable Integrated adjustable sensitivity 10 100 0 8kg 1 8lbs 75 x 100 x 54mm 3 x 4 x 2 approx Command and Control Integrated Power Supply Features Adjustable photocell Adjustable power Telemetry input 8 5mm 0 3 25mm 1 23 5mm 0 9 47mm 1 9 48mm 1 9 ...

Page 5: ...unctioning nB Refer to manufacturer s guide Check that the cable is fully intact and not broken or split Step 2 Set up Camera lens and illumination Check alignment of lamp Check camera lens fully open at night set correctly Check model number to RayLED performance specification to ensure required distance is achievable Step 3 Contact RayLED for further assistance note down Model Angle and Waveleng...

Reviews: