13
iii) Crimp the contact pin to the wire using a proper wire crimper.
Figure 4.9 Crimp the contact pin to the wire
v) Insert the contact pin to the top part of the connector and screw up the cap nut to the top part of the connector.
Figure 4.10 Connector with Cap nut Screwed on
v) Then connect the DC connectors to the inverter. A small click will confirm the connection.
Figure 4.11 Connect the DC Connectors to the Inverter
4.3.2 Connect grid side of the inverter
For all AC connections, 4-10mm² 105 XJ cable is required to be used. Please make sure the resistance of the cable
is lower than 1 ohm. If the wire is longer than 20m, it's recommended to use a 10mm² cable.
There are"L" "N'' '' '' symbols marked inside the connector, the Line wire of grid must be
connected to "L" terminal; the Neutral wire of the grid must be connected to "N" terminal;
the Earth of the grid must be connected to '' ''