2.4 Grid codes

16.3KG

16.3KG

16.3KG

18.3KG

18.3KG

18.3KG

21.6KG

98.1%

97.5%

99.9%

97.8%

97.2%

99.9%

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated

Integrated (Type III)

Integrated (Type III)

                 

395 x 330 x 185mm

455x390x160mm

     455x390x190mm

LCD

RS485 (Standard), Wifi or GPRS

-25 

 ~ 60 

0-100%

≤ 4000m

< 0.2W

Transformerless

Natural Convection

IP65

< 30dB

5 / 7 / 10 years

C10/11, PEA, MEA, G98, G99, EN50549,CEI 0-21, CEI 0-16, IEC61727, IEC62116, 

IEC60068, IEC61683

IEC 62109-1, IEC 62109-2

EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 61000-6-2,

EN 61000-6-3, IEC 61000-4-16, IEC 61000-4-18, 4-29

Protection

DC Insulation Monitoring

Input Reverse Polarity Protection

Anti-island Protection

Residual Current Monitoring

Over-heat Protection

AC Overcurrent Protection

AC Short-circuit Protection

AC Overvoltage Protection

DC Surge Protection

AC Surge Protection

General Data

Size(Width*Height*Depth)

Weight

User Interface

Communication

Ambient Temperature Range

Relative Humidity

Operating Altitude

Standby Self Consumption

Topology

Cooling

Protection Grades

Noise

Warranty

Certifications & Standards

Grid Regulation

Safety Regulation

EMC

98.1%

97.5%

99.9%

Belgium power Grid.

UK power Grid.

China power Grid, meet Grid standards “CN-NBT”.

France power Grid, meet Grid standards “VDE 0126”.

Poland power Grid.

Germany power Grid, meet Grid standards “BDEW-MV”.

Germany power Grid, meet Grid standards “VDE 0126”.

Italy power Grid, meet Grid standards “CEI 0-16”.

UK power Grid.

Greece Island power Grid.

Czech Republic power Grid, meet Grid standards “EN50438Y2007-CZ”.

India power Grid.

Korea power Grid.

Sweden power Grid.

China power Grid, Grid voltage range

160-290V

Grid frequency range

47-53HZ.

China power Grid, meet standards“CQC ”.

India power Grid, meet Grid standards “IEC61727”.

Brazil power Grid , meet Grid standards “NBT 16150”.

Sri Lanka power Grid, meet Grid standards “IEC61727”.

Mexico power Grid, meet Grid standards “IEC61727 60HZ”.

New Zealand power Grid, meet Grid standards “NZ4777”.

Philippines power Grid, meet Grid standards “IEC61727 60HZ spec”.

Sri Lanka power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Thailand power Grid.

Thailand power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Vietnam power Grid.

Vietnam power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Thailand power Grid.

Thailand power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

Tunisia power Grid.

Tunisia power Grid, Grid voltage range

160-290V, Grid frequency range

47-53HZ.

C10/11

G59

China

VDE0126-FR

EN50549-PL

BDEW-DE

VDE0126-DE

CEI0-16

G83

Greece Island

EN50549-CZ

IEC61727

Korea

EN50549-SW

China-W

China-H

IEC61727-IN

Brazil

IEC61727-SL

Mexico

NZ4777

Philippines

IEC61727-SL-W

PEA

PEA-W

IEC61627-VN

IEC61627-VN-W

MEA

MEA-W

Tunisia

Tunisia-W

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

Description

National/Regional Grid Code

No.

6

Summary of Contents for RI-ENERGYFLOW-3P-15 Series

Page 1: ...428500 Email sales rayleigh com 3P SERIES 15 Solar Inverter User Manual RI ENERGYFLOW 3P SERIES 15 www rayleigh com Rayleigh Instruments Limited Raytel House Cutlers Road South Woodham Ferrers Chelmsf...

Page 2: ......

Page 3: ...3 Installationandstartup 3 1Packageinformation 3 2Installationenvironment 3 3Installationposition 3 4Mountingprocedure 3 5Electricalconnection 3 6StartingtheInverter 4 UserInterface 4 1Ledandkey 4 2LC...

Page 4: ...roughout the manual important information is shown at different levels depending on the character of the information as shown here Safety information important for human safety Violation of warnings m...

Page 5: ...al Keep in mind that the inverter has two voltage carrying sides the PV input and the AC grid Disconnecting the inverter Always disconnect the AC line rst Afterwards disconnect the PV lines Note that...

Page 6: ...y be mandatory in some countrie The selection of PV string output should be based on the optimum utilization of the invested capital compared to the expected annual energy yield from the system This o...

Page 7: ...r Factor cos Output THDi Rated Output Efficiency Max Efficiency Euro Efficiency MPPT Efficiency 6000W 7500W 9000W 12000W 1000V 2 Integrated 140 950V 15000W 18000W 22500W 160V 1 1 16A 16A 4000W 4400VA...

Page 8: ...C 62109 2 EN 61000 3 2 EN 61000 3 3 EN 61000 3 11 EN 61000 3 12 EN 61000 6 2 EN 61000 6 3 IEC 61000 4 16 IEC 61000 4 18 4 29 Protection DC Insulation Monitoring Input Reverse Polarity Protection Anti...

Page 9: ...777 Philippines power Grid meet Grid standards IEC61727 60HZ spec Sri Lanka power Grid Grid voltage range 160 290V Grid frequency range 47 53HZ Thailand power Grid Thailand power Grid Grid voltage ran...

Page 10: ...e still contains electricity so please wait for at least 5 minutes to ensure the capacitors completely release the energy and inverter is not electri ed Note Inverters must be installed by quali ed pe...

Page 11: ...method and mounting location must be suitable for the inverter s weight and dimensions 2 Mount on a solid surface 3 Select a well ventilated place sheltered from direct sun radiation Figure 3 3 Distan...

Page 12: ...edure Setp1 Drill 4 Fix 11 holes in the wall according to the dimensions Step2 Fix the wall mounting bracket on the wall with 4 expansion bolts in accessory bag Setp4 Place the inverter on the wall mo...

Page 13: ...ed AC output current 2 The PE line of inverter should be connected to the earth make sure the impedance of neutral wire and earth wire less than 10 ohm 3 Disconnect the breaker or fuse between the inv...

Page 14: ...ting terminal is ush with the surface of the terminal and the crimping screw torque is 2 0 0 1N m 6 Insert the main part of AC connector into the terminal and hear a click sound 7 Use a wrench to tigh...

Page 15: ...herwise it will cause damage to inverter 3 5 2 Connection to PV string DC input Disassembly the inverter from the Grid 1 Use a screwdriver to press against the unlocked position and hold the wire nut...

Page 16: ...RS485 connecting cables not exceed 1000m 2 Communication lines must be separated from other power lines to avoid communications interference Relay C G N CT _ white black DRM S0 S1 S2 S3 S4 S5 S6 S7 CO...

Page 17: ...will turn into self check mode and the LCD panel will display the remaining time of connect simultaneously After the inverter turn into normal mode it feed electrical energy into grid and LCD panel w...

Page 18: ...wer W Ipv2 A Power W Vac A V Power W Iac A A Power W Fac Hz Power W E today KwH Power W E total KwH Power W SN NO Moudle Firmware M S Country Event list Power W Setting Power W Fault code1 Power W Lan...

Page 19: ...n long in order to enter the setting menu Press pushbutton less than 1 sec several times until you reach the AutoTest Italy menu You need to set the inverter country to CEI 0 21 before testing Press p...

Page 20: ...will automatically run the test until the screen shows Test end Click Read to read the test value and click Export to export the test report After click Read button interface will show the test result...

Page 21: ...y terms of factory you need to supply us with the following information and documentation regarding the faulty unit Product Model No e g R1 8K DS and the serial Number e g 8700831201211006 Copy of the...

Page 22: ...M 2 Check whether the AC side has contacts with earth Grid Faults Fault OVR Fault UVR Fault OFR Fault UFR 1 Wait for 5 minutes if the grid returns to normal PV inverter automatically restarts 2 Make s...

Page 23: ...nge OCPV OCPV2 OCIGrid SciCommLose SpiCommLose BusFault CPU ADFault IGridDevice PLLFault AutoTestFail PVCon gFault FanError LCD display Permanent Fault Fault 1 Disconnect all PV or PV from solar panel...

Page 24: ...ou have any further technical questions about our product please contact us Head Office Rayleigh Instruments Limited Raytel House Cutlers Road South Woodham Ferrers Chelmsford Essex CM3 5WA United Kin...

Reviews: