0049-2702-XXX Alliance Series Modems – USER MANUAL
08/05/2010
Rev. A
Page 48 of 197
-
DTE Control of ALB (ALB- DTE Ctrl’ed)
All modes (except half-duplex and V.13)
Analog loopback (ALB) testing can be initiated from the DTE via pin 18. Positive voltage
activates the test, whereas negative voltage results in normal operation. Disabling this option
keeps the modem from responding to pin 18.
-
DTE Control of RDL (RDL- DTE Ctrl’ed)
All
modes
Remote digital loopback (RDL) testing can be initiated from the DTE via pin 21. Positive
voltage activates the test, whereas negative voltage results in normal operation. Disabling this
option keeps the modem from responding to pin 21.
-
Test Mode (TM to EIA)
All
modes
This option controls pin 25, the test mode (TM) indicator, on the RS-232 interface connector.
(Alternately, pin 25 may be used for analog loopback control. For details, see Appendix D.)
NORMAL
TM output is high (active) only during test modes.
TRUE
TM output is always high.
MODEM SETUPS
The options listed below, through RTS-CTS Delay, are available via the MODEM SETUPS
screens.
-
Carrier Detect Level
All
modes
This option selects the carrier detect level. To make a selection, first select either LEASED or
DIAL from the CARRIER DET. LVL screen, depending on your application. The appropriate
carrier detect level screen will then be displayed.