8.1 Axiom tech spec
Power
Axiom™ 7
Axiom™ 9
Axiom™ 12
Nominal supply voltage
12 V dc
Operating voltage
range
8 V dc to 16 V dc
Fuse requirements
• Inline fuse = 7 Amp, or
• Thermal breaker = 7 Amp
Max current
• Chartplotter — 2.5A
• RV & DV — 5.5A
• Chartplotter — 3A
• RV — 6A
LEN
1
Environmental
Axiom™ 7
Axiom™ 9
Axiom™ 12
Operating temperature
range
-25°C to + 55°C
Storage temperature
range
-30°C to + 70°C
Humidity
up to 93% @ 40°C
Water ingress
protection
IPx6 and IPx7
LCD specification
Axiom™ 7
Axiom™ 9
Axiom™ 12
Size (diagonal)
7.0”
9.0”
12.1”
Type
TN
(T
wisted
Nematic)
IPS (In-Plane Switching)
Color depth
24 bit
Resolution
WVGA 800 x 480
WXGA 1280 x 800
Ratio
5:3
16:10
Illumination
1200
n
i
ts
/
1200
cd/m
2
Viewing angle (T/B/L/R)
60/70/70/70
88/88/88/88
Maximum allowable
wrongly illuminated
pixels
0
1
Number of
simultaneous touches
2
1 to 16
Data connections
Axiom™ 7
Axiom™ 9
Axiom™ 12
Transducer
• DV variant = 9 pin
DownVision™ type
connector
• RV variant = 25 pin
RealVision™ type
connector
25 pin RealVision™ type connector
NMEA 2000
1 x DeviceNet female connector built into power cable
Accessory connection
1 x USB Micro AB connection
Network
1 x RayNet type SeaTalkhs ™ connector 10/100 Mbits/s
72