1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Waterproof fuse holder containing a suitably-rated inline fuse must be fitted.
For suitable fuse rating, refer to:
In-line fuse and thermal breaker ratings
.
Important:
Observe the recommended fuse / breaker ratings provided in the product’s documentation,
however be aware that the suitable fuse / breaker rating is dependent on the number of devices
being connected.
Implementation — direct connection to battery
• Where connection to a power distribution panel is not possible , the power cable supplied with
your product may be connected directly to the vessel's battery, via a suitably rated fuse or breaker.
• The power cable supplied with your product may NOT include a separate drain wire. If this is the
case, only the power cable’s red and black wires need to be connected.
• If the power cable is NOT supplied with a fitted inline fuse, you MUST fit a suitably rated fuse or
breaker between the red wire and the battery’s positive terminal.
• Refer to the inline fuse ratings provided in the product’s documentation.
• If you need to extend the length of the power cable supplied with your product, ensure you
observe the dedicated
Power cable extensions
advice provided in the product’s documentation.
1
Waterproof fuse holder containing a suitably-rated inline fuse must be fitted.
For suitable fuse rating, refer to:
In-line fuse and thermal breaker ratings
.
2
Product power cable.
3
Drain wire connection point.
Battery connection scenario A:
Suitable for a vessel with a common RF ground point. In this scenario, if your product’s power cable is
supplied with a separate drain wire then it should be connected to the vessel’s common ground point.
Battery connection scenario B:
Suitable for a vessel without a common grounding point. In this case, if your product’s power cable is
supplied with a separate drain wire then it should be connected directly to the battery’s negative
terminal.
37