13.3 Radar troubleshooting
No connection can be made to the scanner
Possible
Causes
Possible Solution
Radar powered
down
• If the scanner product has shut down, power it up by opening the Radar app
and selecting the
Power
icon.
• A Quantum Radar will shut down after 30 minutes if neither a wired (RayNet) ,
nor a wireless (Wi-Fi) connection can be made to a MFD.
Radar not
transmitting
• Select
Transmit
for the relevant Radar scanner from the Radar app.
Missing or
incorrect Wi-Fi
credentials
• If using a wireless (Wi-Fi) connection, check that you have entered the correct
SSID and passcode for your Radar. Both the SSID and passcode are provided
on the Radar scanner’s packaging, and are also shown on the serial number
label on the underside of the product.
Damaged or
disconnected
Power cable /
RayNet cable
1.
Check that the cable connectors are fully inserted and locked in position.
2. Check the power supply cable and connectors for signs of damage or
corrosion, replace if necessary.
3.
With the product turned on, try flexing the cable near to the display connector
to see if this causes the product to re-boot/loose power, replace if necessary.
4.
Check the vessel’s battery voltage, the condition of the battery terminals
and power supply cables, ensuring connections are secure, clean and free
from corrosion, replace if necessary.
5. With the product under load, using a multi-meter, check for high voltage
drop across all connectors/fuses etc (this can cause the product to reset/turn
off), replace if necessary.
6. Check condition of relevant breakers and fuses, replace if necessary. If
the breaker keeps tripping or fuses keep blowing, contact a Raymarine
authorized dealer for assistance.
Open Array
power in Off
position
• Ensure Open Array power switch is in the On position.
Software
mismatch
between
equipment
may prevent
communication
• Ensure all Raymarine products contain the latest available software, check the
Raymarine website:
for software compatibility.
Displayed bearing is different to the true bearing
Possible
Causes
Possible Solution
Bearing
alignment
adjustment
required
• Carry out the Bearing Alignment procedure.
Radar will not initialize (Voltage control module (VCM) stuck in “sleep mode”
Possible
Causes
Possible Solution
Intermittent or
poor power
connection
Check power connection at VCM. (Voltage at input = 12 / 24 V, Voltage at output
= 40 V)
132