7.1 General cabling guidance
Cable types and length
It is important to use cables of the appropriate type and length.
• Unless otherwise stated only use cables supplied by Raymarine.
• Where it is necessary to use non-Raymarine cables, ensure that they are of correct quality and
gauge for their intended purpose. (e.g.: longer power cable runs may require larger wire gauges to
minimize voltage drop along the run).
Cable routing
Cables must be routed correctly, to maximize performance and prolong cable life.
• Do NOT bend cables excessively. Wherever possible, ensure a minimum bend diameter (Ø) of
200 mm (7.87 in) / minimum bend radius (R) of 100 mm (3.94 in).
• Protect all cables from physical damage and exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or doorways, or close to moving or hot objects.
• Secure cables in place using cable clips or cable ties. Coil any excess cable and tie it out of the way.
• Where a cable passes through an exposed bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or fluorescent lights.
• Always route data cables as far away as possible from:
– other equipment and cables,
– high current carrying AC and DC power lines,
– antennas.
Strain relief
Use adequate strain relief for cabling to ensure that connectors are protected from strain and will not
pull out under extreme sea conditions.
Circuit isolation
Appropriate circuit isolation is required for installations using both AC and DC current:
• Always use isolating transformers or a separate power-inverter to run PC’s, processors, displays
and other sensitive electronic instruments or devices.
• Always use an isolating transformer with Weather FAX audio cables.
• Always use an isolated power supply when using a 3rd party audio amplifier.
• Always use an RS232/NMEA converter with optical isolation on the signal lines.
38
Summary of Contents for CYCLONE
Page 2: ......
Page 4: ......
Page 8: ...8...
Page 20: ...20...
Page 28: ...28...
Page 40: ...Rear exit 1 Mounting surface 2 Power and RayNet connectors 3 Power and RayNet cables 40...
Page 42: ...42...
Page 52: ...52...
Page 58: ...58...
Page 64: ...64...
Page 69: ...Chapter 12 Operation Chapter contents 12 1 Operation instructions on page 70 Operation 69...
Page 80: ...80...
Page 84: ...84...
Page 88: ......
Page 91: ......