11.1 Radar scanner initial power on test
With all cables correctly and securely connected to the radar scanner, and access to a multifunction
display (power OFF):
1. Ensure the radar scanner power switch is set to ON.
2. Power on the multifunction display.
The radar scanner should enter Standby mode.
3.
If necessary, adjust the lighting and contrast on the multifunction display.
11.2 Radar check
Warning: Radar scanner safety
Before rotating the Radar scanner, ensure all personnel are clear.
Warning: Radar transmission safety
The radar scanner transmits electromagnetic energy. Ensure all personnel are
clear of the scanner when the radar is transmitting.
Checking the radar — RayNet displays
These instructions apply to multifunction displays running LightHouse™ 3 software.
1. Select a Radar page.
The ‘
Off/Not Connected
’ message is displayed.
2. Select
On
to power up your radar.
This process will take approximately 70 seconds.
The scanner should now be transmitting and receiving.
3. Check that the radar screen is operating correctly.