Angle
Distance
Angle
Distance
0°
18.5 mm (0.73 in)
13°
12.1 mm (0.48 in)
1°
18.0 mm (0.71 in))
14°
11.6 mm (0.47 in)
2°
17.5 mm (0.69 in)
15°
11.1 mm (0.44 in)
3°
17.1 mm (0.67 in)
16°
10.6 mm (0.42 in)
4°
16.6 mm (0.65 in)
17°
10.0 mm (0.40 in)
5°
16.1 mm (0.63 in)
18°
9.5 mm (0.37 in)
6°
15.6 mm (0.61 in)
19°
9.0 mm (0.35 in)
7°
15.1 mm (0.59 in)
20°
8.4 mm (0.33 in)
8°
14.6 mm (0.57 in)
21°
7.9 mm (0.31 in)
9°
14.1 mm (0.56 in)
22°
7.3 mm (0.29 in)
10°
13.6 mm (0.54 in)
23°
6.8 mm (0.27 in)
11°
13.1 mm (0.52 in)
24°
6.2 mm (0.24 in)
12°
12.6 mm (0.50 in)
25°
5.6 mm (0.22 in)
Mounting the transducer
The transducer should be mounted following the steps below.
Important:
• Only perform the installation with your vessel out of the water.
• Do NOT lift or suspend the transducer using its cable.
• Ensure that the transducer body is supported during installation.
• Do NOT remove the label attached to the transducer cable, as it helps to ensure correct
connection.
• Do NOT overtighten the hull nut or anti-rotation bolt. Overtightening can cause damage to the
hull and / or transducer which may result in water leaking into the vessel.
32