Connection
Connects to
Suitable
cables
5
HS 1 (Handset
station 1)
connection
Raymic
handset or
Adaptor cable
Raymic
handset’s
fitted cable.
6
HS 2
(Handset
station 2)
connection
Raymic
handset or
Adaptor cable
Raymic
handset’s
fitted cable.
7
Hub
connection
DO NOT
CONNECT
8
N2K (NMEA
2000)
connection
SeaTalkng ® /
NMEA 2000
backbone
The supplied
DeviceNet to
SeaTalkng ®
adaptor
cable or a
DeviceNet
spur cable.
Bare end wire connections
Your product is supplied with bare end wire connections.
You must ensure that ALL bare end wires are adequately
protected from short circuit and water ingress.
Bare ended wire connections
It is recommended that bare ended wire connections are
made by soldering or using crimp connectors and then
protected by wrapping the connection in insulation tape.
Unused bare ended wires
Any unused bare ended wires should be folded back
and wrapped in insulation tape.
4.3 Power connection
The power supply should be connected as shown below:
1.
Base station
2. Power supply positive (+) Red wire
3.
Power supply negative (-) Black wire
4.
Suitable waterproof connection (Base station is
supplied with bullet crimps on power supply wires.)
5. 12 V dc power source
Warning: 12 Volt dc only
This product must only be connected to a
12 volt dc power source.
Warning: Positive ground
systems
Do not connect this unit to a system which
has positive grounding.
In-line fuse and thermal breaker
ratings
The following in-line fuse and thermal breaker ratings
apply to your product:
In-line fuse rating
Thermal breaker rating
10 A
7 A (if only connecting
one device)
Note:
• The suitable fuse rating for the thermal breaker
is dependent on the number of devices you are
connecting. If in doubt consult an authorized
Raymarine
®
dealer.
• Your product’s power cable may have fitted in-line
fuse, if not then you can add an in-line fuse to the
positive wire of your products power connection.
Grounding
This product is grounded through the 0 V dc negative
wire on the power cable and does not require a drain
(shield) to be connected to the base station’s ground
terminal.
Power distribution
Recommendations and best practice.
• The product is supplied with a power cable, either
as a separate item or a captive cable permanently
attached to the product. Only use the power cable
supplied with the product. Do NOT use a power cable
designed for, or supplied with, a different product.
• Refer to the
Power connection
section for more
information on how to identify the wires in your
product’s power cable, and where to connect them.
• See below for more information on implementation for
some common power distribution scenarios.
27