background image

Chapter 1: Important information

Warning: Product installation
and operation

• This product must be installed and

operated in accordance with the
instructions provided. Failure to do so
could result in personal injury, damage
to your vessel and/or poor product
performance.

• Raymarine recommends certified

installation by a Raymarine approved
installer. A certified installation qualifies
for enhanced product warranty benefits.
Contact your Raymarine dealer for
further details, and refer to the separate
warranty document packed with your
product.

Warning: Potential ignition
source

This product is NOT approved for use in
hazardous/flammable atmospheres. Do
NOT install in a hazardous/flammable
atmosphere (such as in an engine room
or near fuel tanks).

Warning: Product grounding

Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions provided.

Warning: Positive ground
systems

Do not connect this unit to a system which
has positive grounding.

Warning: Switch off power
supply

Ensure the vessel’s power supply is
switched OFF before starting to install this
product. Do NOT connect or disconnect
equipment with the power switched on,
unless instructed in this document.

Caution: Power supply
protection

When installing this product ensure the
power source is adequately protected
by means of a suitably-rated fuse or
automatic circuit breaker.

Water ingress

Water ingress disclaimer

Although the waterproof rating capacity of this
product meets the IPX6 standard, water intrusion
and subsequent equipment failure may occur if the
product is subjected to commercial high-pressure
washing. Raymarine will not warrant products
subjected to high-pressure washing.

Disclaimer

Raymarine does not warrant that this product is
error-free or that it is compatible with products
manufactured by any person or entity other than
Raymarine.

Raymarine is not responsible for damages or injuries
caused by your use or inability to use the product,
by the interaction of the product with products
manufactured by others, or by errors in information
utilized by the product supplied by third parties.

EMC installation guidelines

Raymarine equipment and accessories conform to
the appropriate Electromagnetic Compatibility (EMC)
regulations, to minimize electromagnetic interference
between equipment and minimize the effect such
interference could have on the performance of your
system

Correct installation is required to ensure that EMC
performance is not compromised.

Note:

In areas of extreme EMC interference,

some slight interference may be noticed on the
product. Where this occurs the product and the
source of the interference should be separated by
a greater distance.

For

optimum

EMC performance we recommend

that wherever possible:

• Raymarine equipment and cables connected to

it are:

– At least 1 m (3 ft) from any equipment

transmitting or cables carrying radio signals e.g.
VHF radios, cables and antennas. In the case
of SSB radios, the distance should be increased
to 7 ft (2 m).

– More than 2 m (7 ft) from the path of a radar

beam. A radar beam can normally be assumed
to spread 20 degrees above and below the
radiating element.

• The product is supplied from a separate battery

from that used for engine start. This is important to
prevent erratic behavior and data loss which can
occur if the engine start does not have a separate
battery.

• Raymarine specified cables are used.

• Cables are not cut or extended, unless doing so is

detailed in the installation manual.

Important information

7

Summary of Contents for RMK-10

Page 1: ...2016 Raymarine UK Limited 81367 1 Document number 11 2016 Date English en US INSTALLATION INSTRUCTIONS RMK 10...

Page 2: ...ystems Inc All other trademarks trade names or company names referenced herein are used for identification only and are the property of their respective owners This product is protected by patents des...

Page 3: ...rant products subjected to high pressure washing Disclaimer Raymarine does not warrant that this product is error free or that it is compatible with products manufactured by any person or entity other...

Page 4: ...to receive full warranty benefits Your unit package includes a bar code label indicating the serial number of the unit You will need this serial number when registering your product online You should...

Page 5: ...marine multifunction displays MFD The keypad is a class 1 PoE Power Over Ethernet device and can be powered either using a suitable network connection that is providing PoE or directly using the dedic...

Page 6: ...f planning any installation It is also useful for any future additions or maintenance of the system The diagram should include Location of all components Connectors cable types routes and lengths 3 2...

Page 7: ...echnical support Caution Installing software updates The software update process is carried out at your own risk Before initiating the update process ensure you have backed up any important files Ensu...

Page 8: ...ore information Electrical interference the product should be mounted far enough away from any equipment that may cause interference such as motors generators and radio transmitters receivers Magnetic...

Page 9: ...o engines or fluorescent lights Always route data cables as far away as possible from other equipment and cables high current carrying AC and DC power lines antennae Strain relief Ensure adequate stra...

Page 10: ...ct grounding Before applying power to this product ensure it has been correctly grounded in accordance with the instructions provided Grounding Dedicated drain wire The power cable supplied with this...

Page 11: ...e with suppression ferrite fitted Direct MFD connection without PoE 1 MFD 2 RayNet network cable 3 RMK keypad 4 Right angled power cable Connected to the alternate power connector Direct MFD connectio...

Page 12: ...ght angled power cable Connected to the alternate power connector 4 Networked MFDs Note Once connected the keypad must be paired with each MFD you want to control with the keypad Cables and connection...

Page 13: ...ting template to the selected location using masking or self adhesive tape 4 Drill 4 holes as indicated on the mounting template to accept the fixings 5 Using a suitable hole saw the size and position...

Page 14: ...ings provided Note The appropriate tightening torque and drill bit size to use depends on the thickness of the mounting surface and the type of material it is made from Note The supplied gasket provid...

Page 15: ...mode on integrated autopilot 10 Power see table below Configura tion Display State Momentary press Press and hold Off Standby Power on 1 Multifunction display On Open Shortcuts page Power off put int...

Page 16: ...The keypad will cycle through displays in the order in which they were paired On multi application pages the and buttons can be used to switch the active application between full and splitscreen 3 Pr...

Page 17: ...ng the device via PoE consider using the keypad s dedicated power connector to supply the power to the device Possible causes for connection issues are Low or inconsistent voltage at the power supply...

Page 18: ...are secure clean and free from corrosion replace if necessary 5 With the product under load using a multi meter check for high voltage drop across all connectors fuses etc replace if necessary Incorre...

Page 19: ...eration of your equipment Complete the following checks on a regular basis Examine all cables for signs of damage or wear and tear Check that all cables are securely connected 34 Chapter 8 Maintenance...

Page 20: ...ecification Operating temperature 25 C to 55 C 13 F to 131 F Storage temperature 30 C to 70 C 22 F to 158 F Relative humidity Maximum 93 Waterproof rating IPx6 IPx7 Wired connections Network PoE 1 x R...

Page 21: ...hand Product name Product identity Serial number Software application version System diagrams You can obtain this product information using the menus within your product Servicing and warranty Raymar...

Page 22: ...help you make the most of your products FAQs and Knowledge Base Raymarine has produced an extensive set of FAQs and a Knowledge Base to help you find more information and troubleshoot any issues Tech...

Page 23: ...ares Item Part number Portrait keypad mat spare R70509 Landscape keypad mat spare R70508 Accessories Item Part number Right angled 2 m 6 6 ft power cable A06070 Straight 2 m 6 6 ft power cable A06049...

Page 24: ...pull the cables through conduits and other obstacles 5 3 RayNet to RayNet right angle coupler adapter Suitable for connecting RayNet cables at 90 right angle to devices for installations where space...

Page 25: ...Net network switch e g HS5 or LightHouse MFD 1 3 Adapter cable with a RayNet male plug on one end and an RJ45 SeaTalkhs waterproof male plug on the other end Connect a legacy G Series GPM 400 C Series...

Reviews: