SeaTalk
hs
patch cables
Cable
Part number
1.5 m (4.9 ft) SeaTalk
hs
patch cable
E06054
5 m (16.4 ft) SeaTalk
hs
patch cable
E06055
10 m (32.8 ft) SeaTalk
hs
patch cable
E06056
15 m (49.2 ft) SeaTalk
hs
patch cable
A62136
20 m (65.6 ft) SeaTalk
hs
patch cable
E06057
4.3 Power connection
Power must be supplied to the camera from an appropriate power
source.
Power connection requirements
• 12 or 24 Vdc nominal supply voltage
• Isolated power supply
• Connected via an appropriately rated thermal breaker or fused
switch.
Power connection colors
Color
Description
Red
Power in +ve (12 / 24 V)
Black
Power in -ve (0 V)
Green
Drain / Ground
Power cable
The power connection is made to a 450 mm (18 in) tail out of the
camera base. Extend this tail with appropriate cable as per the table
below.
Total length (max)
Supply voltage
Cable size
12 V
1.5 mm
2
(16 AWG)
0–8 m (25 ft)
24 V
0.8 mm
2
(18 AWG)
12 V
2.0 mm
2
(14 AWG)
8–16 m (50 ft)
24 V
0.8 mm
2
(18 AWG)
12 V
3.5 mm
2
(12 AWG)
16–24 m (75 ft)
24 V
0.8 mm
2
(18 AWG)
12 V
5.5 mm
2
(10 AWG)
24–32 m (100 ft)
24 V
0.8 mm
2
(18 AWG)
Breakers, fuses and circuit protection
Raymarine recommends that you fit a thermal breaker or fuse for
the camera at the distribution panel.
Camera
Recommended fuse
All models
5 Amp.
Sharing a breaker
Where more than 1 piece of equipment shares a breaker you must
provide protection for the individual circuits. E.g. by connecting an
in-line fuse for each power circuit.
D1
1637-1
+VE bar
Circuit breaker
Fuse
Fuse
-VE bar
Where possible, connect individual items of
equipment to individual circuit breakers.
Where this not possible, use individual in-line
fuses to provide the necessary protection.
Cables and connections
21
Summary of Contents for T303
Page 2: ......
Page 4: ......
Page 6: ...6 T Series...
Page 18: ...18 T Series...
Page 24: ...24 T Series...
Page 28: ...Thin panel mounting D11989 1 Thick panel mounting D11990 1 28 T Series...
Page 40: ...40 T Series...
Page 43: ......
Page 44: ...www raymarine com...