background image

24

ADJUSTMENT STEP 2

Adjust the Force

Force adjustment controls are located on the back panel 
of the motor unit. Force adjustment settings regulate the 
amount of power required to open and close the door.

If the forces are set too light, door travel may be 
interrupted by nuisance reversals in the down direction 
and stops in the up direction. Weather conditions can 
affect the door movement, so occasional adjustment may 
be needed.

The maximum force adjustment range is about 3/4 of a 
complete turn. Do not force controls beyond that point. 
Turn force adjustment controls with a screwdriver.

NOTE: 

If anything interferes with the door’s upward 

travel, it will stop. If anything interferes with the door’s 
downward travel (including binding or unbalanced doors), 
it will reverse.

HOW AND WHEN TO ADJUST THE FORCES

1.  Test the DOWN (close) force

•   Grasp the door bottom when the door is about halfway 

through DOWN (close) travel. The door should reverse. 

Reversal halfway through down travel does not 
guarantee reversal on a 1-1/2" (3.8 cm) obstruction. 
See Adjustment Step 3, page 25.

 If the door is hard to 

hold or doesn’t reverse, DECREASE the DOWN (close) 
force by turning the control counterclockwise. Make 
small adjustments until the door reverses normally. 
After each adjustment, run the opener through a 
complete cycle.

   If the door reverses during the down (close) cycle 

and the opener lights aren’t fl ashing,

 INCREASE 

DOWN (close) force by turning the control clockwise. 
Make small adjustments until the door completes a 
close cycle. After each adjustment, run the opener 
through a complete travel cycle.

 Do not increase the 

force beyond the minimum amount required to close 
the door.

2.  Test the UP (open) force

•   Grasp the door bottom when the door is about halfway 

through UP (open) travel. The door should stop. If the 
door is hard to hold or doesn’t stop, DECREASE UP 
(open) force by turning the control counterclockwise. 
Make small adjustments until the door stops easily 
and opens fully. After each adjustment, run the opener 
through a complete travel cycle.

   If the door doesn’t open at least 5 feet (1.5 m),

INCREASE UP (open) force by turning the control 
clockwise. Make small adjustments until door opens 
completely. Readjust the UP limit if necessary. After 
each adjustment, run the opener through a complete 
travel cycle.

Without a properly installed safety reversal system, 
persons (particularly small children) could be 
SERIOUSLY INJURED or KILLED by a closing garage 
door.
•  Too much force on garage door will interfere with 

proper operation of safety reversal system.

•  NEVER increase force beyond minimum amount 

required to close garage door. 

•  NEVER use force adjustments to compensate for a 

binding or sticking garage door.

•  If one control (force or travel limits) is adjusted, the 

other control may also need adjustment.

•  After ANY adjustments are made, the safety reversal 

system MUST be tested. Door MUST reverse on 
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid 
fl at) on fl oor.

Back Panel

Force Adjustment 
Controls

Antenna

FORCE ADJUSTMENT LABEL

Close Force

Open Force

Summary of Contents for 3245RGD 1/3 HP

Page 1: ...LL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located on the front panel of y...

Page 2: ...r 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PI...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...r is closed Support bracket fastening hardware is required See page 11 Motor Unit FINISHED CEILING Wall Mounted Door Control Extension Spring OR Torsion Spring Header Wall Access Door Safety Reversing...

Page 5: ...Washer 5 16 4 Screw 6ABx1 1 4 2 Screw 6 32x1 2 Self Threading Screw 1 4 14x5 8 2 Insulated Staples 30 Ring Fastener 3 Drywall Anchors 2 Carriage Bolt 1 4 20x1 2 2 Wing Nut 1 4 20 2 Rope Handle SAFETY...

Page 6: ...nut on the trolley to obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor...

Page 7: ...balanced and lubricated garage door An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH 3 ALL repairs to cables spring assemblies and other hardware MU...

Page 8: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possibl...

Page 9: ...e ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing toward the wall The bracket can be mounted ush against the ceiling when cl...

Page 10: ...s not tall enough Open the door all the way and place a 2x4 laid at on the top section beneath the rail If the top section or panel hits the trolley when you raise the door pull down on the trolley re...

Page 11: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to op...

Page 12: ...allowing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adjust screw for snug t Install top screw with care to avoid cracking plastic ho...

Page 13: ...he hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the oor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Sec...

Page 14: ...Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Rei...

Page 15: ...eiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be s...

Page 16: ...oor Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all d...

Page 17: ...ollow the instructions below Cut the end of the safety reversing sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 7 Separate the safety reversing sens...

Page 18: ...orrect wiring between sensors and opener A broken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t Check alignment Check for an open wire to the r...

Page 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...he door if required for your installation Refer to the dotted line optional placement drawing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 WOOD DOOR METAL DOOR Finished Ceiling HORIZONTA...

Page 21: ...alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sec...

Page 22: ...tton The trolley will travel to the fully closed position Figure 5 Figure 6 Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm con...

Page 23: ...ce as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the DOWN limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won...

Page 24: ...by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the...

Page 25: ...bstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY...

Page 26: ...trol is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature ma...

Page 27: ...on To turn off press and hold the Lock button again for 2 seconds The push bar light will stop ashing The Lock feature will also turn off whenever the learn button on the motor unit panel is activate...

Page 28: ...tteries DO NOT recharge disassemble heat above 100 C 212 F or incinerate Care of Your Opener LIMIT AND FORCE ADJUSTMENTS Weather conditions may cause some minor changes in door operation requiring som...

Page 29: ...to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP...

Page 30: ...or unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is...

Page 31: ...be heard 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that...

Page 32: ...ights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people wit...

Page 33: ...hium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope handle assembly 6 41B4494 1 2 Conductor bell wire white white red 7 41A4353 Header bracket with clevis pin fastener 8 4...

Page 34: ...ring assembly RPM sensor KEY PART NO NO DESCRIPTION 11 41A5525 25 Cover 12 41A2818 Limit switch drive retainer 13 41D3452 Limit switch assembly 14 41A2822 1 Interrupter cup assembly 15 41C4398A RPM se...

Page 35: ...Includes visor clip Outside Keylock Opens the garage door automatically from outside when remote control is not handy 8 foot 2 4 m Complete Rail To allow an 8 foot 2 4 m door to open fully 10 foot 3 m...

Page 36: ...o you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESS...

Reviews: