28
THE REMOTE CONTROL BATTERY
The lithium battery should produce power for up to
5 years.
To replace battery, use the
visor clip or screwdriver
blade to pry open the case
as shown. Insert battery
positive side up (+).
Dispose of old battery
properly. Replace the
battery with only 3V2032
coin cell batteries.
NOTICE: To comply with FCC and or Industry Canada (IC) rules,
adjustment or modifications of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE.
Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fi re, explosion or chemical burn:
• Replace ONLY with 3V2032 coin batteries.
• DO NOT recharge, disassemble, heat above 100° C
(212° F) or incinerate.
Care of Your Opener
LIMIT AND FORCE ADJUSTMENTS:
Weather conditions may cause some
minor changes in door operation
requiring some re-adjustments,
particularly during the fi rst year of
operation.
Pages 23 and 24 refer to the limit and
force adjustments. Only a screwdriver
is required. Follow the instructions
carefully.
Repeat the safety reverse test (Adjustment Step 3,
page 25) after any adjustment of limits or force.
MAINTENANCE SCHEDULE
Every Month
• Manually operate door. If it is unbalanced or binding,
call a trained door systems technician.
• Check to be sure door opens and closes fully. Adjust
limits and/or force if necessary (see pages 23 and 24).
• Repeat the safety reverse test. Make any necessary
adjustments (see Adjustment Step 3).
Two Times a Year
• Check chain tension. Disconnect trolley fi rst. Adjust if
necessary (see page 7).
Every Year
• Oil door rollers, bearings and hinges. The opener does
not require additional lubrication. Do not grease the
door tracks.
Every Three to Four Years
• Use a rag to wipe away the existing grease from the
garage door opener rail. Reapply a small layer of white
lithium grease to the rail.
FORCE CONTROLS
LIMIT CONTROLS
Battery
positive
side up (+)