background image

CONNECT THREE BUTTON STATION

Your operator has been supplied with a standard three button
station labeled open-close-stop. Mount three button station in
sight of the door, at a minimum height of 5 feet and away from
moving parts of the door. For proper connection of the three
button station refer to wiring diagram in lid of operator. At this
time also mount warning placard supplied in hardware box
next to three button station.

CONNECT ENTRAPMENT DEVICE

If other than constant pressure wiring type is required, you
must connect a photo electric control series 5000 by Vitector
Fraba, model HAE00056 by Linear Corp., or Miller Electric
reversing edge model ME with blue color band. For proper
connection of device, refer to wiring diagram found in lid of
operator.

            WARNING: Failure to connect a Raynor approved

            reversing device may cause severe injury or death.

WARNING: Do not let children operate the door or
play in the door area. Keep clear of the door it

may move at any time without warning and keep the door

in sight at all times when it is moving.

CONNECT TO POWER SUPPLY

             WARNING: Before beginning any electrical

             hook-up, disconnect quick release arm from
operator using quick release mechanism shown in

Fig. 8. Use caution when releasing trolley arm, it will

swing downward.

Consult local wiring codes prior to permanent installation.

This operator must be properly grounded. Refer to wiring

diagram, found on inside of control box cover, for power

line, push-button, and reversing device connections.

Verify that line voltage and operator voltage shown on the
cover are the same.

5973129-6

TO

PR

EV

EN

T

EN

TR

AP

ME

NT

Do

no

t

st

ar

t

do

or

do

wn

wa

rd

un

le

ss

do

or

wa

y

is

cl

ea

r

WA

RN

IN

G

W

AR

N

IN

G

ATTACH DOOR BRACKET

Some installations may require additional bracing
where door bracket is bolted to door. Fig. 7 shows
the type of bracing recommended by Raynor for the
Trolley Operator. Bracket should be located so holes
on door bracket line up with top rollers on door.

2 x 2 x 1/8 ANGLE

BY OTHERS

MUNTIN

DOOR BRACKET

BY RAYNOR

FIG. 7

TROLLEY CARRIAGE

DOOR BRACKET

CURVED ARM

QUICK RELEASE ARM

FIG. 8

ATTACH DRAWBAR Fig. 8

Move trolley carriage to within 6" of front mounting
bracket by manually turning large pulley at powerhead.
If operator is supplied with a brake, pull disconnect

bolt at back of brake mounting plate to disengage
brake.

Attach quick release arm to trolley carriage. With quick
release arm in vertical position, attach curved portion of

arm assembly to quick release portion using 5/16 x 1"
cap screws, nuts and lock washers furnished in hard-
ware package.

With door in fully closed position attach remaining end of
arm assembly to door bracket with 3/8 x 1" cap screw,
washers and nuts furnished. Arm should connect to door

bracket at hole nearest in line with top rollers of door. See
Fig. 8

Configuration:

Connect to

Sensor 1 Input

Connect to

Sensor 2 Input

Electric Edge Only

X

-

Photo Eye Only

X

-

Photo Eye & Electric Edge

Photo Eye

Electric Edge

Photo Eye & Photo Eye

Photo Eye 1

Photo Eye 2

Monitored Reversing Devices

         WARNING: Install the Photo Eyes NO HIGHER than
         6" (15cm) above the floor.

Note: When an external device, like a 3-button station,
motion detectors, or photo eyes are required, you must use
a wire type of CL2 or equivalent.

Summary of Contents for ControlHoist 2.0 STANDARD

Page 1: ...ist 2 0 PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION IT IS IMPORTANT THAT THIS OPERATOR BE INSTALLED CORRECTLY IN ORDER TO ACHIEVE SAFE AND PROPER OPERATION THIS OPERATOR HAS BEEN SUPPL...

Page 2: ...replace the defective door components Labor charges for installations or repairs shall be the responsibility of the consumer and must be performed by an authorized Raynor Dealer This warranty extends...

Page 3: ...s 9 Do not place hands in area of pulleys V belt sprockets chain or rotating shafts 10 Install warning placard on wall next to push button 11 Attach instruction booklet to wall near push button 12 Do...

Page 4: ...ify delivering VISUAL INSPECTION carrier immediately rail assembly with lug B facing the open end of the rails ing packing material Unpack powerhead and trolley rail assemblies being 5973129 4 electri...

Page 5: ...ng either lag screws or self tapping screws furnished in hardware package Resting powerhead of operator on floor attach front end of rails to front mounting bracket Swing unit into position over door...

Page 6: ...e and operator voltage shown on the cover are the same 5973129 6 TO PRE VEN T ENT RAP MEN T Do not sta rt doo r dow nwa rd unle ss doo rwa y is clea r WAR NIN G W AR NING ATTACH DOOR BRACKET Some inst...

Page 7: ...14 14 12 14 10 14 8 14 6 12 0 5 115 230 14 14 12 14 10 14 8 14 6 12 0 75 115 230 12 14 10 14 8 14 6 12 4 10 1 115 230 12 14 10 14 8 14 6 12 4 10 1 5 230 14 14 12 10 8 MINIMUM WIRE SIZE FOR SINGLE PHA...

Page 8: ...minal Block 1 Terminal Block 2 High Voltage Wire Harness Connection LIGHT CCM NO1 SER C1NC1 NO2 C2NC2 ON OFF OPEN CLOSE ON OFF 24VDC 24VDC 24VAC 24VAC Terminal Block 3 24V DC Power Connection Auxiliar...

Page 9: ...sing RD or RC wiring photo eye s or edge must be selected even though they are not required Note The photo eye or an electric edge must be monitored 5 SENSOR 2 TYPE will display there are three option...

Page 10: ...OFF If a warning light is required select ON Press the stop button to continue 16 If a warning light is ON WARNING TIME will display The time is set in 1 second intervals from 3 seconds to 10 seconds...

Page 11: ...r death 8 SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS Operating the 3 Button Control Station 1 Press OPEN button The door should move in the open direction 2 Press STOP button The door should stop...

Page 12: ...eck manual operation of door Refer to installation instructions 800 page 5972558 1 for guidelines Test all reversing devices once a month for proper operation Test all accessories that may have been s...

Page 13: ...ng Off Stop button pressed or NOT connected On Open button sending signal pressed Off Open button is not sending signal 2 Open D12 6 I Lock D24 7 I Lock D23 On Chain hoist interlock circuit is open ch...

Page 14: ...en limit switch and the open button is pushed This message will display anytime the board is not receiving a signal from the sensor 2 when close button is pressed Whether it is not connected activated...

Page 15: ...minate stress on rollers and cables 1 Sunlight is blocking the receiving photo eye 2 Faulty photo eyes 1 Connect Operator to power source 2 Check voltage at L1 L2 for single phase and at L1 L2 L3 for...

Page 16: ...oard Verify power consumption of the device s before installing You may have to power the device from an external power source using only the contacts of the device to activate the operator 3 The comm...

Page 17: ...use the dry contacts of that relay to activate the device If more than 3 amps of power is being consumed through the auxiliary board then damage to the board may occur 2 There is a 14 pin connector o...

Page 18: ...lied With Raynor Door NOTE Placement of Labels may vary from what is shown Spring Warning Tag Push Button Placard Locate Near Push Button Door Safety Label Bottom Fixture Danger Label Bottom Fixture D...

Reviews: