background image

KG

1

3

9

7

5

KG

1

3

9

7

5

12

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a
minimum height of 5 feet (1.5 m) where small children
cannot reach, and away from moving parts of the door
and door hardware. The installation surface must be
smooth and flat. If installing into drywall (Figure 1),
drill 5/32" holes and use anchors provided. For 
pre-wired installations (as in new home construction),
it may be mounted to a single gang box (Figure 2).

NOTE:

After installation, a green indicator light behind

the cover will indicate proper connection. If not lit, the
Lock and Light features will not function (reverse
wires to correct).

1. Strip 7/16" (11 mm) of insulation from one end of

bell wire and connect to the two screw terminals on
back of door control by color: white wire to 2 and
white/red wire to the 1 (Figure 3). 

2. Remove white cover by gently prying at slot in top

of the cover with a small flat head screwdriver.
Fasten with 6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32x1" machine screws (into gang
box) as follows:
• Drill and install bottom screw, allowing 1/8" (3 mm)

to protrude above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Install top screw with care to avoid cracking plastic

housing. 

Do not overtighten.

• Insert top tabs and snap on cover.

NOTE:

The push bar may stick if the door control is

not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.

3.

(Standard installation only)

Run bell wire up wall

and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit. 

4. Strip 7/16" (11 mm) of insulation from end of bell

wire. Connect bell wire to the quick-connect
terminals as follows: white to white and white/red to
red.

NOTE:

When connecting multiple door controls to the

opener, twist same color wires together. Insert wires
into quick-connect holes: white to white and red/white
to red.

5. Use tacks or staples to permanently attach

entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.

NOTE:

DO NOT connect the power and operate the

opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor Instructions
beginning on page 15.

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires. 
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet (1.5 m),
and away from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

WARNING

CAUTION

WARNING

WARNING

To release wire, push in tab
with screwdriver tip

Door Control
Connections

7/16" (11 mm)

Strip wire 7/16" (11 mm)

Red

Grey

White

Drywall Anchors

Insulated
Staples 

Screw 6ABx1-1/4"
(std installation)

Screw 6-32x1" 
(pre-wired installation)

HARDWARE SHOWN ACTUAL SIZE

Figure 2

LOCK

LIGHT

To Replace
Insert Top
Tabs First

STANDARD WALL MOUNT

Detector
Switch

Push Bar Cover

ON
OFF

Figure 1

24 Volt Bell Wire

PRE-WIRED INSTALLATION

LOCK

LIGHT

To Replace
Insert Top
Tabs First

Detector 

Switch

Push Bar Cover

ON
OFF

1
RED

2
WHIT

E

Door
Control
Terminal
Screws

24 Volt
Bell Wire

(BACK VIEW)

Bottom 
Mounting
Hole

Top 
Mounting 
Hole

Figure 3

Summary of Contents for ULTRA SAFETY SIGNAL 2595RGD

Page 1: ...losed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the...

Page 2: ...roblem 25 26 Programming 27 28 To add or reprogram a hand held remote control 27 To erase all codes 27 3 Button remotes 27 To add reprogram or change a Keyless Entry PIN 28 Repair Parts 29 30 Rail ass...

Page 3: ...ement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or b...

Page 4: ...r 4 SECTIONAL DOOR INSTALLATION Planning Identify the type and height of your garage door Survey your garage area to see if any of the conditions below apply to your installation Additional materials...

Page 5: ...artons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material Parts may be stuck in the...

Page 6: ...pener by inserting a 5 16 18x1 2 washered screw through a hole in each side flange and a matching hole in the bracket Complete the connection by inserting the 8 32x3 8 screw through the back flange an...

Page 7: ...ND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener only on properly balanced and lubricated garage door An improperly balanced door may not reverse when required and cou...

Page 8: ...l line on the header wall 2 5 cm above the high point This height will provide travel clearance for the top edge of the door To prevent possible SERIOUS INJURY or DEATH Header bracket MUST be RIGIDLY...

Page 9: ...rage Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CE...

Page 10: ...ket Rail HARDWARE SHOWN ACTUAL SIZE INSTALLATION STEP 4 Position the Opener SECTIONAL DOOR ONLY A 2x4 laid flat is convenient for setting an ideal door to rail distance Raise the opener onto a steplad...

Page 11: ...he door hits the rail raise the header bracket 8 Grease the top and underside of the rail surface where the trolley slides with rail grease NOTE DO NOT connect power to opener at this time To avoid po...

Page 12: ...nnect terminals as follows white to white and white red to red NOTE When connecting multiple door controls to the opener twist same color wires together Insert wires into quick connect holes white to...

Page 13: ...n overhand knot at least 1 2 5 cm from the end of the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handl...

Page 14: ...he black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the...

Page 15: ...talled on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without...

Page 16: ...will not support the bracket securely wall installation is recommended Wall installation Place the bracket against the wall with curved arms facing the door Be sure there is enough clearance for the s...

Page 17: ...y if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or...

Page 18: ...ollows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the doo...

Page 19: ...ty Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as sho...

Page 20: ...Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 3 7 5 cm of travel If door still won t close complet...

Page 21: ...Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to clos...

Page 22: ...un the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the...

Page 23: ...emote controls and one SAFETY SIGNALTM Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener...

Page 24: ...to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds A single blink indicates that the timer is reset to 1 1 2 minutes Repeat the procedur...

Page 25: ...easy to install CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS Weather conditions may cause some minor changes in door operation requiring some readjustments particularly during the first year of ope...

Page 26: ...nts to force or travel limits The need for occasional adjustment of the force and limit settings is normal Weather conditions in particular can affect door travel 11 The door reverses for no apparent...

Page 27: ...ight goes out approximately 6 seconds All previous codes are now erased Reprogram each remote or keyless entry you wish to use 1 Press and release the learn button on the motor unit The learn indicato...

Page 28: ...y PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4...

Page 29: ...SCRIPTION 1 41A5276 24 Motion detecting door control panel 2 973RGD 3 button remote control 3 10A20 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope handle as...

Page 30: ...et 8 108D68 1 Lens 9A 30B530 Capacitor 56uF 9B 30B529 Capacitor 40uF 9C 41A5637 Resistor 10 41A3150 Terminal block w screws 11 81C253 Limit switch drive retainer 12 41A5640 Limit switch assembly KEY P...

Page 31: ...er to operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This temporary password can be l...

Page 32: ...the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defect...

Reviews: