11
10. CONTROLS (DIGITAL
MODELS)
Your heater incorporates digital safety controls and
indicators to ensure its safe, reliable operation (for models
with analog controls, see "Controls & Indicator Lamps
(Analog Models)" on
page 9
).
Water Pressure Switch
: Prevents operation when the
pump is OFF. The unit requires 5 PSI (34.5 kPa) minimum
pressure.
Digital Water Temperature Control
: The pool water
temperature is controlled by the heater’s digital control
system, which gives you the option of two settings: one for
the desired spa temperature and the other for the desired
pool temperature. Additionally, as mentioned earlier, the
unit is compatible with most ‘2-wire’ and ‘3-wire’ control/
automation systems.
Figure 7. Digital Water Temperature Control
Defrost Sensor
: Prevents unit operation if ambient air
temperature falls below a predetermined safe minimum
(approximately 42°–48°F (5.6°–8.9°C), based on humidity).
The compressor will shut OFF but the fan will continue to
run.
Delay Timer
: Prevents the compressor from short-cycling,
which could damage or destroy the hermetic motor/
compressor. Upon water temperature control satisfaction,
or other circuit interruptions, this solid-state device will
prevent compressor restart for approximately 5-minutes.
11. DIGITAL CONTROLS
OPERATING
INSTRUCTIONS
The electronic board has the capability of memorizing
two different programmed temperature settings as follows
(refer to
Figure 7
):
• For a pool, maximum 95°F (35°C)
• For a spa, maximum 104°F (40°C)
To Select Pool or Spa Mode
To have access to either one of these programs, press the
SET key until you see P _S and by pressing the UP or
DOWN key you can switch to POL or SPA.
To Increase the Desired Water
Temperature (Pool or Spa Mode)
Push the SET key until you see POL or SPA. The
programmed temperature will be displayed. Press the UP
arrow to increase the temperature setting one degree at a
time.
To Lower the Desired Water
Temperature (Pool or Spa Mode)
Push the SET key until you see POL or SPA. The
programmed temperature will be displayed. Press the
DOWN arrow to decrease the temperature setting one
degree at a time.
Once the control has been programmed to the desired
pool water temperature, the programmed temperature will
be displayed for approximately 5-seconds. Then the digital
display will display the actual pool water temperature.
To make the Board a Pool ONLY Board, call 800-260-2758
for instructions.
To Select Temperature in °C or °F
Press the SET key until you see F _C. By pressing the
UP or DOWN key you can switch to °F or °C. Once the
temperature display mode has been programmed it will
be displayed for approximately 5-seconds, then the digital
display will return to the actual pool water temperature in
the mode that you have chosen.
12. HEAT/COOL OPERATION
(MODELS 6350HC AND
8350HC ONLY)
The heat/cool model is designed to both heat and cool the
pool. To select heat or cool mode, push the SET key until
H/C is displayed. Press the DOWN arrow key to select
heating (hea), or the UP arrow key to select cooling (col).
Set the desired setpoint temperature as described earlier
in this manual.
NOTE:
Once the control has been programmed to
the desired pool water temperature, the programmed
temperature will be displayed for approximately 5
seconds. The digital display will then show the actual
pool water temperature.
NOTE:
Remove the pool/spa blanket and turn on any
fountains, sprays or other water features to speed
cooling.
Summary of Contents for 5350 Series
Page 20: ...20 H C F DUAL CAPACITOR V V 208V 230V Single Phase Digital Models 5350 6350 8350 8360...
Page 21: ...21 208V 230V 3 Phase Analog Models 5350 6350 8350...
Page 22: ...22 208V 230V 3 Phase Digital Models 5350 6350 8350...
Page 23: ...23 460V 3 Phase Analog Model 8354...
Page 26: ...26...
Page 28: ...28...
Page 29: ...29...
Page 30: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...
Page 60: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...