14
C. Condensation Seems Excessive
Heaters can produce a large amount of condensation
(water) during operation. If you suspect that the unit is
leaking:
Fault Code
Description and Solutions
OFF
The desired programmed temperature point is lower than 60°F (15°C).
LP & LP3
Shortage of refrigerant gas in the unit or faulty low pressure control. The unit will show (LP3) after 3 LP
faults and shuts down the unit and pool pump for protection. If this occurs, you should call for service.
HP & HP6
Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The unit will show
(HP6) after 6 HP faults. This will stop the unit for protection.
FLo & FL3
Possible causes:
• The filter is in backwash position.
• The filter pump is stopped.
• The filter is dirty.
• Shortage of water to pool pump.
• Water pressure switch must be adjusted or it is broken.
• The unit is in the protection mode and will show (FL3), press any key to restart the unit. FL3 code will
stop the unit and pool pump.
FS
Unit is in the defrosting cycle.
(The fan works but the compressor is stopped.)
- -
Keypad is pressing down on both buttons. Replace keypad.
Table D. Control Board Fault Codes — Digital Models
1. Use a pool chemistry test kit to confirm there is no
chlorine in the condensation. Or,
2. Shut the unit OFF and leave the filter pump running
to see if the water stops dripping. If the water stops
dripping, the unit is not leaking.
19. SERVICE CALL
VERIFICATION
NOTE: The Raypak Service number is 800-260-2758.
Before you make a service call, first determine if the
problem is:
• Warranty Service
• Unit operation (power supply, water flow, or time
clock adjustment)
NOTE:
The MANUFACTURER IS NOT RESPONSIBLE for
these adjustments.
Power Supply
• Verify that all circuit breakers are reset and working
properly.
• If the temperature display or the Power lamp on the
control panel still does not light, contact the installing
dealer, since it may be a power problem requiring an
electrician.
Water Flow
• Verify that the pool filter is clean to provide good flow.
• Verify that valves are properly positioned to allow
adequate water flow through the unit.
• If the Water Flow lamp (analog models) on the control
panel still does not light, and water is circulating in
the pool, verify that all valves are positioned correctly.
Time Clock Adjustment
Verify that the time clock is set to permit the unit to run long
enough to heat properly.
Summary of Contents for 5350 Series
Page 20: ...20 H C F DUAL CAPACITOR V V 208V 230V Single Phase Digital Models 5350 6350 8350 8360...
Page 21: ...21 208V 230V 3 Phase Analog Models 5350 6350 8350...
Page 22: ...22 208V 230V 3 Phase Digital Models 5350 6350 8350...
Page 23: ...23 460V 3 Phase Analog Model 8354...
Page 26: ...26...
Page 28: ...28...
Page 29: ...29...
Page 30: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...
Page 60: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...