6
Figure 1. Installation Clearances
• Automatic chemical dosing devices and salt
chlorinators are usually more efficient in heated
water. Unless controlled, they can lead to excessive
chlorine level which can damage your heater.
• Further advice should be obtained from your pool
or spa builder, accredited pool shop, or chemical
supplier for the correct levels for your water.
• Recirculation of cold discharge air back into the
evaporator coil will greatly reduce the unit’s heating
capacity and efficiency.
• This unit features an ‘up-flow’ discharge for quiet
operation. Air is pulled up through the evaporator coil
and discharged through the top grill. Allow at least 5
ft (1.5 m) clearance above the unit for unrestricted air
discharge. Do NOT install the unit under a porch or
deck. Refer to
Figure 1
.
• To minimize water piping, locate the unit as close as
possible to the existing pool pump and filter.
• If the location of the heater is below the water line of
the pool, the water pressure switch might need to be
adjusted or an external water flow switch might be
needed.
• Irrigation water should be directed away from the
heater—water spray can damage the heater.
• Rain water run off: the heater can withstand normal
rain. Install rain gutters to prevent direct steams of
rain water to the heater.
• It is important to keep the area next to the heater
clear of shrubs, bushes and chemicals containers.
They could prevent air from circulating fully through
the heater, and will affect the operation of the heater,
or damage it.
• When installed in areas where freezing temperatures
can be encountered, drain the water circuit to
prevent possible freeze-up damage. See
"Freeze
Protection" on page 12
.
• For high wind installation requirements, refer to
Figure 2
and
Figure 3
.
GAS
HEATER
AIR
FLOW
IN
AIR
FLOW
IN
AIR FLOW OUT
12" MIN
(30.5 cm)
60" MIN
(152.4 cm)
F10082
3' MIN
(91.4 cm)
HEAT
PUMP
Summary of Contents for 5350 Series
Page 20: ...20 H C F DUAL CAPACITOR V V 208V 230V Single Phase Digital Models 5350 6350 8350 8360...
Page 21: ...21 208V 230V 3 Phase Analog Models 5350 6350 8350...
Page 22: ...22 208V 230V 3 Phase Digital Models 5350 6350 8350...
Page 23: ...23 460V 3 Phase Analog Model 8354...
Page 26: ...26...
Page 28: ...28...
Page 29: ...29...
Page 30: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...
Page 60: ...30 NOTES Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 www raypak com...