background image

Raypak’s Next Generation Condensing
Heater

Time-honored  technologies  unite  with  cutting-edge  advancements  in
Raypak’s  new  XTherm

 

vertical  heater.  Never  before  has  a  vertical

heater  provided  both  the  installer  and  pool  builder  such  installation
flexibility,  ease-of-commissioning,  reliability  and  long-term
performance. Small space, not a problem. The XTherm has one of the
smallest  installed  footprints  of  any  vertical  condensing  heater.    Our
compact  design  makes  it  the  perfect  choice  for  those  hard  to  reach
retrofit  projects.  Raypak’s  XTherm  is  built  with  commercial-grade
components  and  materials.  From  our  steel  channel  base  to  our
stainless steel flue wrapper, and secondary heat exchanger, you can tell
the XTherm is built to last. It’s easy to handle and install, but still user
friendly  to  service.  Now  is  the  perfect  time  to  take  a  closer  look  at
Raypak.

Flexibility

Industry-leading  vent  length  allowances  afford  greater  vent  location
options,  thus  reducing  wasted  space.  Vent  versatility  is  further
enhanced  by  the  self-tuning  combustion  system  which  compensates
for unusual chimney and vent configurations.

Category  IV

-  CSA-certified  97%

efficiency  at  full  fire  for  water  heaters  in
pool  applications. When  the  job  requires
high efficiency, XTherm meets your needs.
The  XTherm  can  use  either  AL29-4C
stainless  steel,  PVC  or  CPVC  for  venting.
Just  specify  the  D-32  vent  option  when
using PVC vent.

At the heart of every Raypak XTherm is a unique integral evaporator
system  -  the  first  defense  against  condensation  in  the  primary  heat
exchanger.  Raypak’s  evaporator  system  collects  and  re-evaporates
condensate which may form during initial start-up.

Simplicity

The Raypak XTherm will precisely heat your pool. Utilizing the latest
European  technology  for  the  combustion-components,  the  optimum
fuel-air  ratio  is  maintained  throughout  the  entire  range  of  the  load-
tracking  operation.  The  XTherm  automatically  self-tunes  to
accommodate  the  widest  range  of  gas  supply  pressures.  The  high
quality  integrated  blower-gas  valve  is  self-correcting  and  allows
smooth operation with fluctuating gas supply pressures.  The Raypak
XTherm is cutting edge technology with atmospheric simplicity

.

Key Features

PVC vent capable - optional at time of order

3 models from 1,000,000 to 2,000,000 BTUH

97% thermal efficiency at full fire in pool applications

Minimum continuous inlet water temperature (50°F)

Small footprint, less than 11 square feet 

AB 1953 low lead compliant 

On-board diagnostic center, real English, no codes

All models indoor/outdoor certified

Complete cabinet protects all controls and wiring

Meets all current Low NOx regulations, including the new
2010 SCAQMD revisions

Suitable for altitudes up to 10,000 ft.
(derate above 5,000 ft.)

Equipped with all cupro-nickel, bronze and stainless steel 
waterways

X

treme Performance

97%

thermal efficiency!

X

treme Performance

97%

thermal efficiency!

Think Raypak

2

We use commercial grade Cupro-
Nickel finned tubing in the primary
heat exchanger. Standard copper-
based heat exchangers can not
stand up to the harsh environment
of commercial pool heating. Your
customers expect the best and
Raypak delivers with professional
grade commercial pool heaters.

Optional PVC Vent

Think Green

6200.12-E_XTherm Brochure 8 page  3/29/11  10:58 AM  Page 3

Summary of Contents for Xtherm 1005

Page 1: ...Can be vented with PVC pipe ...

Page 2: ...sation in the primary heat exchanger Raypak s evaporator system collects and re evaporates condensate which may form during initial start up Simplicity The Raypak XTherm will precisely heat your pool Utilizing the latest European technology for the combustion components the optimum fuel air ratio is maintained throughout the entire range of the load tracking operation The XTherm automatically self...

Page 3: ...ous inlet water temperature 12 Cold Water Run Pump The XTherm comes factory equipped with a built in Cold Water Run system This advanced water control system keeps the inlet water temperature to the primary heat exchanger above 120 F regardless of the incoming water temperature It constantly self adjusts and regulates the incoming water flow while still maintaining a constant ΔT in the heat exchan...

Page 4: ... be drawn from inside the heater through screened plenum openings See photo above right 4 Gas Inlet The XTherm will operate at 100 full rate with gas pressures as low as 4 0 w c 5 Water Outlet 6 Water Inlet The XTherm can accept as low as 50 F continuous inlet water temperature without damage to the primary heat exchanger 7 Access Panel to Cold Run Pump Easily removable access panel even when unit...

Page 5: ...ce Minimum Do not install on carpeting Note Local codes may require increased clearances Heater Side Model Pool Heater Output Efficiency MBTUH Input MBTUH 1005 999 969 97 1505 1500 1455 97 2005 1999 1939 97 PHYSICAL DATA 1005 55 1 8 45 47 1 8 36 1 2 1 1 4 6 40 1 16 11 1 2 6 47 1 8 8 1 16 6 1 16 1065 12 10 1505 67 1 8 57 59 1 16 38 1 2 1 1 4 8 52 1 16 12 5 8 8 59 1 8 8 3 16 6 1 16 1234 12 14 2005 8...

Page 6: ...is based on maintaining an indoor swimming pool at 80ºF for 6 months of the year and using a fuel cost of 1 00 per therm How to use the table below 1 Select the desired temperature of the pool water 2 Determine the mean average temperature of the month in which the pool will be used 3 Subtract the mean temperature from the desired swimming temperature The difference is the temperature rise 4 Calcu...

Page 7: ...m comes equipped with a microprocessor controlled diagnostic control center that displays its information on a 2x20 character LCD display in plain English This control monitors system safeties ignition faults and system status while storing up to 16 reported faults Raypak s diagnostic center monitors the fault outputs of the Fenwal ignition control converting the Fenwal s fault codes into real Eng...

Page 8: ... Display Lights 4 Temperature Controller with 3 Water Sensors TempTracker Mod Multiple Heater Controller TempTracker Mod up to 16 heaters Hot Surface Ignition System 1 try 3 try High Low Gas Pressure Switches Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed Manual Reset Adjustable Automatic Reset Adjustable Shipped Loose Low Water Cut Off 24V With Manual Reset and Test B...

Reviews: