Safety Guidelines

Before operating with the printer, please read the following safety guidelines to identify the potential risks which 

you may experience during the usage. When using the printer, make sure to comply with the related requirement 

defined in the manual already and take appropriate precautions in advance.
Any operation which was failed to fulfill with the requirement defined in the safety guidelines may result in 

personal injury or equipment damage, and the corresponding consequences should be taken by the users.

The device shall be operated by professional staff

Keep away from children

Disassembly or modification is strictly prohibited

It is strictly prohibited to disassemble or modify the device  without authorization. Do not use 

accessories which are not designated by RAYSHAPE officially.

Please keep the device, resin material and other accessories out of the reach of children.

Operators must carefully read and understand the safety guide and operation manual, then 

operate with the device correctly as required.

Risk of UV exposure

When the printer and post-curing device are working, please keep protective cover / door 

closed normally.

If any operation or maintenance work should be proceeded while the printer is working, 

the anti-UV goggles shall be worn accordingly.

The specification of power must meet the operating requirements of the device.

A grounded electrical outlet should be applied.

Replaced with a new one before usage if it was found that the power  cable is aging 

or damaged.

Risk of electric shock

Both the printer and post-curing device were designed basing on the principle of UV  light curing 
and there is UV light available  inside the device during operation, the risk of UV exposure shall 
be avoided accordingly.

Summary of Contents for Edge E1

Page 1: ...Edge E1 User Manual V1 0...

Page 2: ...ciple 7 Installation and Debugging 8 Installation Requirement 9 Packing List 10 Equipment 11 Installation and Connection 12 Preparation and Setup 13 Interface Introduction 15 Printing 22 Post Processi...

Page 3: ...1 General Information...

Page 4: ...have any improvement or modification opinions on this document and the product or If there is any error please inform us in time Thank you for your valuable comments on our products 2022 Suzhou Laisai...

Page 5: ...not designated by RAYSHAPE officially Please keep the device resin material and other accessories out of the reach of children Operators must carefully read and understand the safety guide and operati...

Page 6: ...tant gloves should be worn during the operation of separating printed parts from the platform The blade of the shovel should not be orientated to your body during the usage Please keep good ventilatio...

Page 7: ...5 Product Information...

Page 8: ...in air filter in building chamber Touch screen 7 color touchscreen Connectivity USB2 0 Wireless network 2 4GHz 5 8GHz Ethernet Input 100 240VAC 50 60Hz Rated power 320 W Software Control system Self...

Page 9: ...D printer The resin tank contains photosensitive resin In the first stage of printing the printing platform that can move up and down on the Z axis is close to the bottom of the resin tank The LCD scr...

Page 10: ...8 Installation and Debugging...

Page 11: ...ibration sources A level and stable platform is required for Edge E1 away from fire heat and vibration sources Keep the cover closed during printing During the printing process please try not to open...

Page 12: ...lease film 1 4 Resin tank lid 2 5 Power cord 1 6 User manual 1 7 USB drive 1 8 Spare screws 6 No List Quantity 1 Plastic box 2 2 Plastic nippers 1 3 Scraper 1 4 Shovel blade 1 5 Disposable filter 80 m...

Page 13: ...over 07 USB port 02 Printing platform 08 Ethernet interface 03 Resin tank 09 Power switch 04 Touch screen 10 Power interface 05 Air filter 11 Fan port 06 Quick clip 12 Nameplate 04 07 03 05 01 06 10 0...

Page 14: ...kept at a distance of more than 20cm from the wall to make sure that the cover could be fully opened The table should be flat and stable and avoid direct sunlight to the printer Connection of cables 1...

Page 15: ...bayonet then take away the platform outward Remove resin tank Release knobs on both sides of the resin tank outwards Please align the printing platform with the cantilever bayonet and slide inward ho...

Page 16: ...and clean it regularly If needed please replace with a new protective film Screen test Place a piece of A4 paper on the screen close the cover click Mono Screen Test the screen will project a square...

Page 17: ...15 Interface Introduction...

Page 18: ...on Preview of printing part Return to former interface Start printing Printing in progress Time remaining Progress bar Pause Continue Terminate Interface for printing task Taskbar Task list Load the f...

Page 19: ...e related operation Step 2 The resin would be cured as soon as the projection finished Click NEXT and make sure that the cover was closed to avoid UV light exposure Completion of printing Click to ret...

Page 20: ...afterward It is not recommended to deal with that by using the tools such as tweezers since the solid resin with such thickness was quite brittle Step 3 Clean up the cured resin within the tank Step...

Page 21: ...s The value in would be added by 0 1mm The value in would be subtracted by 0 1mm The value of Maximum Z axis travel Printing parameters Parameters for printing accuracy correction for adjusting zoom r...

Page 22: ...wireless network After the connection the printer will be identified by the host computer through the IP address then it is allowed to deliver the printing task online ShapeWare connect the device th...

Page 23: ...of replacement for air filter Remind every month or never remind Mono Screen Test Test whether the LCD is working normally Please close the cover and do not look directly at the screen during the tes...

Page 24: ...Printing...

Page 25: ...ther the release film is damaged and any foreign matter is available in the resin tank if it is an empty one If there is residual resin available in the tank use the plastic scraper to scrape the bott...

Page 26: ...he resin material into the resin tank The liquid level of the resin should be kept between line min and max Contacting with resin directly may lead to skin irritation and please wear disposable gloves...

Page 27: ...25 Post Processing...

Page 28: ...x It is recommended to equip with ShapeWash washing unit Post processing Remove the printing platform Rotate counterclockwise to release the handle and pull outward to remove printing platform Remove...

Page 29: ...Place the blade as parallel as possible to the platform to avoid scratching Please take resin material out of the tank if it will be not consumed in 3 days make sure to get it filtered before store th...

Page 30: ...leaning solvent carefully in order to remove residual resin After the preliminary cleaning please spray cleaning solvent on the model After cleaning the surface of the model is dry and free of sticky...

Page 31: ...29 Maintenance...

Page 32: ...Clean the printing platform with cleaning solvent carefully in the meanwhile Maintenance work in case that printing part falls off during printing In case of such problems as part falling off the pri...

Page 33: ...31 Troubleshooting...

Page 34: ...g package do not match The resin is inconsistent with the resin selected during slicing Please confirm whether it matches The tank is seriously damaged Pour out the resin in the tank check the quality...

Page 35: ...33 Service...

Page 36: ...sportation as well 5 Non warranty circumstances Equipment failure caused by human reasons or force majeure Failure to provide valid proof of purchase The performance and reliability of the equipment i...

Page 37: ...device Enter the menu TOOLS CONFIG AND LOG FILES EXPORT THE LOG Export export the running log file of the device which will be saved in the root directory of the USB disk Photos and videos Some fault...

Page 38: ...suggestions feedback rayshape3d com Your feedback is greatly appreciated and your comments and suggestions will be sent to our sales R D and technical support departments to help us provide better pr...

Page 39: ...37 Warranty Card...

Page 40: ...adio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not...

Page 41: ...W0500012 Suzhou Laisai Intelligence Technology Co Ltd 86 400 0983 356 www rayshape3d com Room 101 Building 6 No 59 Jiangnan Avenue Changshu City Jiangsu Province China...

Reviews: