4. Technical Specification

BL24-STD

BL24-EM

Input Voltage

110-254V AC

Input Current (230Vac, full load)

0.15A

0.16A

Consumption

20W/34W

24W/37W

Power Factor (230Vac, full load)

>0.97

Mains Frequency

50/60Hz

Inrush Current  (I

peak

 @50%)

20A, ∆t < 300µs

Total Harmonic Distortion (230Vac, full load)

<10%

IP Rating

IP66/67

Weight (std)

5Kg

6Kg

Dimensions

See previous pages for line diagrams

ATEX  and IECEx and UKEX Rating

See above

Twidth

Inrush Current Typical Curve

Ipeak

Summary of Contents for SPARTAN SPZ Series

Page 1: ...uctions 2 Installation 3 Maintenance 4 Technical Specification 5 Declaration of Conformity The SPARTAN series of explosion protected bulkheads are specialist devices certified for use in specific oper...

Page 2: ...sive jointing compound to screw threads such as PSU cover and external earth points During installation ensure exterior surface of the product is not in direct contact with a dissimilar metal such as...

Page 3: ...g SPARTAN Bulkhead Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use Raytec recommend using M6 Mar...

Page 4: ...T M8 SCREW ITEM 3 WITH M8 SPRING WASHER ITEM 4 TO BOTH SIDES OF STIRRUP AS SHOWN BELOW AND FULLY TIGHTEN D C 4 1 2 3 A B 4 3 2 1 C F E D 3 POSITION STIRRUP TO PREFERRED ANGLE AND SECURE USING REMAININ...

Page 5: ...940 A 00044 NO MODIFICATIONS ALLOWED WITHOUT THE APPROVAL OF THE AUTHORISED PERSON IF IN DOUBT ASK B Thompson 27 10 2021 9 6 8 4 5 2 7 1 3 6 3 4 6 5 ITEM NO DESCRIPTION QTY 1 M8 FIBRE WASHER 2 2 L BR...

Page 6: ...r looping 4mm2 cable only one cable should be connected to each terminal block connection Wire the Mains cable into the terminal block Provision has been made for this and identified as the E Earth L1...

Page 7: ...supply Lasts for few minutes only Spartan Intelligent Emergency Operation Guide 7 The battery fuse located within the Bulkhead housing on emergency variants is disconnected after final manufacturing...

Page 8: ...the possibility of having more than one unit undergoing the test at the same time LED indication c Self test Carried out at a random time every 3 months Checks the battery s capacity and lamp s condit...

Page 9: ...cables to power supply remove four M6 bolts from rear of light engine and pull the light engine assembly clear Re fitting a light engine is a reversal of the above procedure 5 The unit has one indepe...

Page 10: ...30Vac full load 0 15A 0 16A Consumption 20W 34W 24W 37W Power Factor 230Vac full load 0 97 Mains Frequency 50 60Hz Inrush Current Ipeak 50 20A t 300 s Total Harmonic Distortion 230Vac full load 10 IP...

Page 11: ...Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 Max number of fittings allowed per MCB Based on 230V MCB Type Rating BL24 STD BL24 EM B 10A 11 10 B 16A 17 15 B 20A 25 22 B 25A 35 32 C 10A 24 20 C 16A...

Page 12: ...bulkhead luminaires standard and emergency Certification Body CML New Port Road Ellesmere Port CH65 4LZ Certificate Numbers Zone 1 CML13ATEX3007 IEC Ex CML14 0001 CML21UKEX3099 Zone 2 CML17ATEX4231 IE...

Page 13: ...and Safety Requirements has been assessed by reference to the following harmonised designated standards EN 60079 0 2018 EN 60079 7 2015 A1 2018 EN 60079 18 2015 A1 2017 EN 60079 31 2014 And also 2014...

Page 14: ...raytecled com Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom Raytec Americas Tel 1 613 270 9990 sales raytecled com Raytec Systems Inc 800 30...