WARRANTY

12

0

RAYTECH USA, Inc. warrants to the original purchaser of any new TR-1 or TR-1P, that it will be free from
defects in material and workmanship under normal use and service for a period of 5 years from the original date of
shipment. This 5-year warranty is provided at no cost to the end user, for the products covered under this warranty
if the products are returned on each calendar year from the original date of shipment, prepaid, to Raytech USA, for
system evaluation.
The obligation of RAYTECH USA, Inc. under this warranty is limited, in its exclusive option, to repair, replace, or
issue credit for parts or materials which prove to be defective, and is subject to the purchaser's compliance with the
RAYTECH USA, Inc. warranty claim procedure as set forth within this manual.
This warranty covers only those parts and/or material deemed to be defective resulting from the

manufacturer’s

workmanship. The liability of RAYTECH USA, Inc. shall be limited to the repair, replacement, or issuance of
credit for parts deemed defective within the meaning of this warranty. Costs for labor or other expenses that may
have occurred incidental to the inspection, repair, replacement, or issuance of credit for such parts and/or materials
shall be the sole responsibility of purchaser.  This warranty shall not apply to any accessories, parts, or materials
not manufactured or supplied by RAYTECH USA, Inc.

Equipment must be returned prepaid with a Return Material Authorization (RMA) to:

RAYTECH USA, Inc.

or

RAYTECH GmbH

118 S. 2

nd

Street

Oberebenstrasse 11

Perkasie, PA 18944

CH-5620 Bremgarten

USA

Switzerland

Tel. 1 267 404 2676

Tel. + 41 56 640 0670

Fax. 1 267 404 2685

Fax. + 41 56 640 0674

www.RaytechUSA.com

www.Raytech.ch

LIMITATION OF WARRANTY

The foregoing warranty shall not apply to defects resulting from improper and unauthorized modifications or
misuse and abuse of the product, negligence, alteration, modification, faulty installation by the customer,

customer’s agents or employees. Attempted or actual dismantling, disassembling, service or repair by any per

son,

firm, or corporation not specifically authorized in writing by RAYTECH USA, Inc.
Defects caused by or due to handling by carrier, or incurred during shipment, trans-shipment, or other move.
Inadequate maintenance by the customer, second source supplied software or interfacing, operation outside the
environmental limits, or improper site preparation.

Exclusive remedies provided herein are the customer’s sole and exclusive remedies.

RAYTECH USA, Inc. shall not be liable for any damages resulting from the use of this equipment whether direct,
indirect, special, incidental, or consequential damages, or whether based on contract, tort, or any other legal theory.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED.

Summary of Contents for TR-1

Page 1: ...S 2nd Street Perkasie PA 18944 USA Tel 888 4 THE SPY Tel 267 404 2676 Fax 267 404 2685 Single Phase Battery Operated Automatic Transformer Turns Ratiometer Test System Model TR 1 Model TR 1P Instruct...

Page 2: ...s 1 0 2 Uncrating Procedure 2 0 3 Introduction 3 0 4 Technical Specifications 4 0 5 Front Panel Description 5 0 6 Typical Display Screens 6 0 7 Transformer Ratio Testing 7 0 8 General Notes on Testing...

Page 3: ...s BEFORE APPLYING POWER Make sure the transformer to be tested is cleared and removed from operation GROUND THE INSTRUMENT To minimize shock hazard the instrument must be connected to a properly groun...

Page 4: ...rd TR 1P If any of the above items are missing or damaged please contact your local representative or Raytech USA Inc immediately RAYTECH USA Toll free service support telephone 1 888 4 THE SPY Note T...

Page 5: ...readings on site with laboratory precision The TR 1 TR 1P applies a preset test voltage on the HIGH winding side of the transformer and measures back through the LOW side of the transformer The result...

Page 6: ...Instruction Manual and instrument carry case with shoulder strap TR 1P includes paper refills for the panel mount printer TR 1 FEATURES Automatic measurements of Turns Ratio and Current Automatic det...

Page 7: ...inter allows the user to print out stored results or current results The single button on the printer is for Form Feed To tear paper pull paper towards the front of the instrument against the serrated...

Page 8: ...ge Selector Test Voltage Selector CT Mode Screen 40V selected Screen CT Auto selected License Screen Setup Screen Test in progress After test display Firmware is 0 85 Serial No is 272 100 Pre test scr...

Page 9: ...ormer For example The High Side Winding may contain 960 Turns Low Side Winding 440 Turns Therefore Note 3 Phase Transformers Turns Ratio Voltage Ratio are usually different IMPORTANT NOTE 1 Hooking up...

Page 10: ...ecked by connecting all of the measuring lead clips of the test set all together The GO Will appear in the test screen No Ratio test can be performed however Turn the system on by pressing the Rotary...

Page 11: ...gh the X leads The X leads must always have lower voltage than the H leads or an error will be displayed When testing Current transformers take care that the test leads are correctly attached In certa...

Page 12: ...or group number of 3 would have a phase displacement of 3 x 30 or 90 The low side winding has a lagging displacement with respect to the high side winding PHASE The transformer phase that is being tes...

Page 13: ...2 X0 A H1 H0 X0 X1 YN yn 6 B H2 H0 X0 X2 C H3 H0 X0 X3 A H1 H0 X2 X0 YN yn 8 B H2 H0 X3 X0 C H3 H0 X1 X0 A H1 H0 X0 X3 YN yn 10 B H2 H0 X0 X1 C H3 H0 X0 X2 A H1 H0 X1 X2X3 YN y 0 B H2 H0 X2 X1X3 C H3...

Page 14: ...H1 X0 X2 C H3 H2 X0 X3 A H1 H3 X2 X0 YN zn 7 B H2 H1 X3 X0 C H3 H2 X1 X0 A H1 H3 X0 X3 YN zn 9 B H2 H1 X0 X1 C H3 H2 X0 X2 A H1 H3 X1 X0 YN zn 11 B H2 H1 X2 X0 C H3 H2 X3 X0 A H1 H0 X1 X2 YN d 1 B H2...

Page 15: ...H1 X1 X3 C H3 H2 X2 X1 A H1 H3 X3 X1 D d 6 B H2 H1 X1 X2 C H3 H2 X2 X3 A H1 H3 X2 X1 D d 8 B H2 H1 X3 X2 C H3 H2 X1 X3 A H1 H3 X2 X3 D d 10 B H2 H1 X3 X1 C H3 H2 X1 X2 A H1 H3 X1 X0 D yn 1 B H2 H1 X2...

Page 16: ...X1X3 A H1 H3 X2X3 X1 D y 7 B H2 H1 X1X3 X2 C H3 H2 X1X2 X3 A H1 H3 X2 X1X3 D y 9 B H2 H1 X3 X1X2 C H3 H2 X1 X2X3 A H1 H3 X1X2 X3 D y 11 B H2 H1 X2X3 X1 C H3 H2 X1X3 X2 A H1 H2H3 X1 X0 D zn 0 B H2 H1H3...

Page 17: ...X0 X1 Y yn 6 B H2 H1H3 X0 X2 C H3 H1H2 X0 X3 A H1 H2H3 X2 X0 Y yn 8 B H2 H1H3 X3 X0 C H3 H1H2 X1 X0 A H1 H2H3 X0 X3 Y yn 10 B H2 H1H3 X0 X1 C H3 H1H2 X0 X2 A H1 H2H3 X1 X2X3 Y y 0 B H2 H1H3 X2 X1X3 C...

Page 18: ...2 X2 X0 A H1 H2H3 X0 X1 Y zn 7 B H2 H1H3 X0 X2 C H3 H1H2 X0 X3 A H1 H2H3 X2 X0 Y zn 9 B H2 H1H3 X3 X0 C H3 H1H2 X1 X0 A H1 H2H3 X0 X3 Y zn 11 B H2 H1H3 X0 X1 C H3 H1H2 X0 X2 A H1 H2H3 X1 X2 Y d 1 B H2...

Page 19: ...ement to use this calculation chart is that the connections to the transformer be made exactly as indicated in the previous charts See pages 10 to 15 Config Multiply reading With this factor to get Tu...

Page 20: ...sible causes for these messages 1 Faulty transformer under test 2 Low inductive low resistive loads such as windings without cores 3 Device under test was not properly demagnetized ERRATIC OR ERRONEOU...

Page 21: ...e responsibility of purchaser This warranty shall not apply to any accessories parts or materials not manufactured or supplied by RAYTECH USA Inc Equipment must be returned prepaid with a Return Mater...