Magnetic Sonde
7 Installation and Maintenance
Edition:003
19
4423
a) 108-010.NG001 E01 - Connect the connecting cable of the magnetic sonde to
junction box Type 134-089.
b) 108-010.NG002 E01 - Connect the connecting cable of the magnetic sonde directly
to the related system or equipment.
c) 108-010.NG003 E01 - Connect the connecting cable of the magnetic sondes to
junction box Type CP 500JB.
CAUTION!
Hazard due to interchange the cable connection of the magnetic
sondes
Risk of false course display at the connected system or equipment
• Observe the correct installation of the cables.
Note
The upper magnetic sonde is mirror-inverted to the lower magnetic sonde. Due to
the opposed sense of rotation of the lower magnetic sonde, the Signals S1 and S3
must be interchanged, see
.
d) 108-010.NG004 E01 - Connect the connecting cable of the magnetic sonde to
junction box Type CP 500JB.
2. Install the connecting cable without buckling.
CAUTION!
Hazard due to buckling the connecting cable
Risk of material damage
• Install the connecting cable without buckling.
Close Up
1. Adjust the magnetic sonde, see
.
7.3.4
Change Sense of Rotation
Requirements
Required Conditions
No conditions
Required Persons
1 Maintainer
1.0 h
Support Equipment
No support equipment
Consumables, Materials and Expendables
No consumables, materials and expendables
Summary of Contents for 108-010.NG001 E01
Page 6: ...Magnetic Sonde List of Figures 4423 IV Edition 003 ...
Page 8: ...Magnetic Sonde List of Tables 4423 VI Edition 003 ...
Page 10: ...Magnetic Sonde List of Abbreviations 4423 VIII Edition 003 ...
Page 55: ...12 02 10 ...
Page 56: ...07 10 11 Lut 23 11 11 ...
Page 57: ...07 10 11 Lut 23 11 11 ...
Page 58: ...12 01 10 ...
Page 62: ...Magnetic Sonde Illustrated Spare Parts Catalog 4 4 Edition 001 Intentionally left blank ...
Page 73: ...Magnetic Sonde Illustrated Spare Parts Catalog Edition 001 15 4423 Intentionally left blank ...
Page 80: ...Magnetic Sonde Illustrated Spare Parts Catalog 4423 22 Edition 001 Intentionally left blank ...