Magnetic Sonde
7 Installation and Maintenance
Edition:003
25
4423
► The nominal resistance must be 146 Ohms.
Close Up
1. If the measured resistances deviate from the nominal values, replace the magnetic
sonde, see
.
7.4.2
Remove Magnetic Sonde
Requirements
Required Persons
1 Maintainer
1.0 h
Support Equipment
Tool, operating
05-0000 02
1 EA
Consumables, Materials and Expendables
No consumables, materials and expendables
Spares
No spares
Safety Conditions
WARNING!
Danger due to nonadherence to safety instructions
Risk of death or serious injury and material damage
• Observe all general safety instructions.
• Observe all safety instructions for maintenance.