Installation and Service manual
Compass STD 22
104
Edition: May 20, 2005
3646/110--233.DOC010302
3.4.3.5
Setting the CAN bus address
Every CAN bus user must be reachable via an address.
This address may be assigned in the CAN bus system only once.
In the gyro compass, this address is set with the DIP switch.
The CAN bus address for compasses can be set within a range from 10
(10)
to 19
(10)
.
The address 00
(10)
may not be used.
Indications
Comments, Information
Switch B 37 (DIP switch)
1 2 3 4 5 6 7 8
OPEN
OFF
ON
B38
B39
each time pressed
changes downwards
each time pressed
changes upwards
Below mentioned table shows the agreement for the CAN bus addresses within a
compass system.
Device(s)
CAN--Bus--Address
Operator Units
01 to 09
Sensors
(GPS--compass)
10 to 13
Sensors
(Gyro Compass)
14 to 19
Distribution Units
20 to 29