Installation and Service manual
Compass STD 22
Compass STD 22 Compact
122
Edition: Feb. 17, 2006
3646/110--233.DOC010302
5.1.1
Adjustments of parameters (in ascending order of function)
DIP--
switch
Step
Display
Function
Push but-
ton B38
(left)
Push but-
ton B39
(right)
1
0
ALEr
Alignment error setting
decrease
increase
1+2
0
Addr.
Address setting CAN bus
down-
wards
upwards
1 to 8
0
Fr.Cl
Clearing Logs
1
E.L.Ci
Error Log Clear, whole log will be cleared
choose
hold to 0 to
clear
2
Y.h.Cl
Years, hours Clear
choose
hold to 0 to
clear
6
0
130.1
Fan, display and follow--up test
------------
----------------
5
0
--FU--
Follow--up system manual operation,
Function check of RoT
turns cw
turns ccw
7
0
FUoF
Follow--up system turn off for service
------------
activate
2
0
nNEA
NMEA telegram setting
1
nN1
NMEA telegram repetition 1Hz
choose
set
2
nN10
NMEA telegram repetition 10Hz
choose
set
3
HE.ro
Heading telegram with ROT
choose
set
4
HE.----
Heading telegram without ROT
choose
set
5
SECY
Activate SEC
choose
set
6
SECn
Deactivate SEC
choose
set
7
oELY
SEC with oil residual error
choose
set
8
oELn
SEC withot oil residual error
choose
set
9
ddUY
System with DU
choose
set
10
ddUn
System without DU
choose
set
11
nMSy
NMEA with SEC
choose
set
12
nMSn
NMEA without SEC
choose
set
1+2+3
0
Chn1
Output channel 1, type of telegram
1
HSEr
Select for heading serial
choose
set
2
nNEA
Select for NMEA
choose
set
3
Chn2
Output channel 2, type of telegram
4
HSEr
Select for heading serial
choose
set
5
nNEA
Select for NMEA
choose
set
2+3
0
P ro
ROT polarity setting
choose
set
1
ro
Positive polarity for ROT
choose
set
2
ro --
Negative polarity for ROT
choose
set
3
0
A180
Settling phase bypass
choose
set