Installation and Service manual
Compass STD 22
Compass STD 22 Compact
124
Edition: May 20, 2005
3646/110--233.DOC010302
5.1.2
Adjustments of parameters (in ascending order of their appearance)
DIP--
switch
Step
Display
Function
Push but-
ton B39
(right)
Push but-
ton B38
(left)
8
0
GYro
Reading measured data of the gyro
1
Enco
Encoder value
choose
display
2
ALEr
Alignment error
choose
display
3
SEC
SEC value
choose
display
4
Pbor
24 V ships mains after input filter 12--32 V
choose
display
5
Co14
14 V for 60 V inverter
choose
display
6
P--En
15 V for encoder supply
choose
display
7
P--60
60 V stabilized / ferrite transformer bridge
choose
display
8
Co19
19 V from ferrite transformer
choose
display
9
IndA
Current of ferrite transformer bridge
choose
display
10
Co31
Voltage for heating circuit
choose
display
11
C
°
--U
Voltage on heater element
choose
display
12
--C
°
--
Supporting liquid temperature
choose
display
13
Li--U
Supporting liquid level
choose
display
14
Co73
73 V from ferrite transformer
choose
display
15
78--U
78 V stabilited for gyro AC converter
choose
display
16
GY--U
Gyro supply voltage
choose
display
17
GY--A
Gyro supply current
choose
display
18
Co15
15 V from ferrite transformer
choose
display
19
P--15
15 V stabilized
choose
display
20
P--24
24 V for pump AC converter
choose
display
21
U--Pu
24 V AC pump voltage
choose
display
22
A--Pu
Pump current
choose
display
23
Ab9r
Follow up voltager W1/W2
choose
display
24
Pr--S
Software sensor pcb
choose
display
25
Pr--P
Software Power Supply PCB
choose
display
26
Pr61
Software MC1 outer sphere pcb
choose
display
27
Pr62
Software MC2 outer sphere pcb
choose
display
28
runY
Operating years
choose
display
29
runh
Operating hours
choose
display
30
0007
future purpose
31
0008
future purpose
7+8
0
E.L.01
Errors according to error logbook
choose
number of
errors
1
E.L.02--24 Errors according to error logbook
choose
number of
errors
Clear selected error logbook
Hold 10s to clear