Compass
STD 22
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
187
Edition: May 20, 2005
3646/110--233.DOC010302
-- Close the distilled water filling opening with the screw.
Use a new sealing ring.
---
Place the outer sphere in the compass enclosure.
--
Pay attention to the two locking pins (Figure 67/4) on the
closure.
---
Hold the outer sphere with both hands and guide it under the snap closures on the
pendulum joint.
---
Using the thumbs, press down and engage the two snap closures.
---
Carefully turn the outer sphere through 90
°
and repeat the process with the other two
snap closures. The outer sphere is now fastened to the pendulum joint.
---
Guide the cable with the plug to the left around the outer sphere and plug it in as shown
in (Figure 66/2).
---
Close the door of the enclosure and fasten it with screws, paying attention to the
earthing strip.
When the power supply is switched on, the compass is ready for use again. Run the
heating and settling in stage as described in section 3.4.3.2.