Installation and Service manual
Compass STD 22 Compact
64
Edition: July 1, 2005
3646/110--233.DOC010302
Note: The procedure to adjust essential operating modes
is described on the next four pages.
Set the repetition rate of the NMEA heading data output, the output with or without
ROT (Rate of Turn), with or without oil residual error for the speed error correction and
the setting of a connected Data Distribution Unit
( Data Distribution Unit is not for
STD 22 Compact Gyro Compass)
.
1 heading data transmission 1 telegram per second.
10 heading data transmission 10 telegrams per second.
HE.ro heading with ROT.
HE.---- heading only
SECY heading data incorporating Speed Error Correction
SECn heading data without Speed Error Correction
oELY Speed Error Correction with oil residual error
(recommended setting
→
SEC)
oELn Speed Error Correction without oil residual error
ddUY with connected Data Distribution Unit
(only for STD 22)
ddUn without Data Distribution Unit
(for STD 22 Compact absolute necessary)
nMSY NMEA output with SEC
nMSn NMEA output without SEC
The indications in the flashing display are selected.
Switch B37 (DIP switch)
OPEN
B38
B 38
B39
B 39
1
X
1X
2X
1X
continued on next page