Distribution Unit
138--118
DISTRIBUTION
UNIT
17
3647.DOC010302
Edition: Sept. 05, 2005
1
2
3
4
5
6
7
8
9
10
11
12
13
Fig.9:
I/O PCB (138--118.101. E10)
No.
Designation at the
I/O PCB E10
Remark
Fig.9/1
Plug B35
Connection of Course bus to the I/O PCB.
Fig.9/2
Plug B9
Connection of Step--output.
Fig.9/3
Fuse E11
Protection (0,25A, slow) 35V DC of the
Step--output at plug B9.
Fig.9/4
Plug B8
Connection of Step--output.
Fig.9/5
Fuse E 10
Protection (0,25A, slow) 35V DC of the
Step--output at plug B8.
Fig.9/6
Plug B7
Connection of Step--output.
Fig.9/7
Fuse E9
Protection (0,25A, slow) 35V DC of the
Step--output at plug B7.
Fig.9/8,9
and 10
LED H47, 48 and 49
Image of the Step--outputs
Fig.9/11
Plug B6
Connection of Course Printer.
Fig.9/12
Plug B5
Connection of RoT (analog).
Fig.9/13
Plug B3
24V DC connection to supply the repeaters
connected at the output channels 1 to 8.