Distribution Unit
138--118
34
3647.DOC010302
Edition: Sept. 05, 2005
4.2.3
General information in use of the DIP--Switch and push buttons
The normal operation of the all DIP--Switches is the “DOWN”--position.
This means the respective switch is closed.
In the upper position the respective switch is open and by this, a mode can be selected
and adjusted.
After a switch is set into the upper position, a mode can be selected by the the push but-
ton on the left of the display (push button B23).
Before setting the selected mode the display--information does not blink.
After acknowledgement of selected mode with the push button on the right of the display
(push button B22) the display information is blinking -- this means selected mode is set.
After setting a mode all switches have to be set into the down--position (exception CAN--
bus address).
4.2.3.1
Setting of DV--bus address
For DV--bus application in the meaning of information to distribution unit for DV--bus
operation and DV--bus address for the distribution unit see manual no.: 3648 “Operator
unit 130--613” under section “DV--bus application”.