Distribution Unit
138--118
DISTRIBUTION
UNIT
39
3647.DOC010302
Edition: Sept. 05, 2005
4.2.3.4
Adjustments of NMEA Formats
The Distribution Unit can provide for each output one of three
different data formats (Course bus, NMEA1 and NMEA2).
Selected format can be recognized by the respective
LED colour.
The content of the course bus format cannot be changed, but
both NMEA formats can be adjusted concerning to telegram--
type and repetition rate.
Procedure for NMEA1:
OPEN
DIP--Switch B20
B23
B22
Fig.24:
DIP--Switch position to adjust the NMEA1 interface
-- Switch 1 of the DIP--Switch into the upper position.
Operation of push
button B23
Display
Interface
after switching (B20)
switch 1 into the
upper position
nME1
NMEA Channel1
1x
nME1.0
NMEA 1.0sec
2x
nME0.1
NMEA 0.1sec
3x
EHdT
HEHDT--Telegram
4x
CHdT
HCHDT--Telegram
5x
IHdG
HCHDG--Telegram
6x
IroT
TIROT--Telegram*
7x
EroT
HEROT--Telegram*
*Adjustment of turn rate see section 4.2.3.7