Distribution Unit
138--118
52
3647.DOC010302
Edition: Sept. 05, 2005
6
Adjustments
6.1
Adjustment of magnetic sonde
This adjustment should be performed only be well trained
technicians.
Necessary tools and measuring instruments
-- Screw driver to adjust potentiometer
-- Voltmeter
-- Iron tool to influence the magnetic sonde
TP0
TP12
TP11
R155
R113 = SCALE
B2
E10
Switch B41
Fig.31: Testpoint at the I/O PCB to adjust the magnetic sonde
Switch B41 has to be closed always. Switch position to the left.