Installation and Service manual
Compass STD 22
Compass STD 22 Compact
118
Edition: Feb. 17, 2006
3646/110--233.DOC010302
5.1
Overview of functions of all DIP switch settings
Serial
no.
DIP switch setting
Function
1
Normal operation
2
Setting compass zero (Alignment error)
3
Set the repetition rate (1s/100ms) of the
NMEA heading data output and the output
with or without ROT
4
Set the CAN bus address
(for gyro compass STD 22 only)
5
Set the interfaces for Channel 1 and
Channel 2 (compass outputs)
6
Set the ROT turning direction
(Port +; STB --)
7
Bypass the settling phase
(Service only)
8
Set the speed source for SEC
9
Check connected course receivers (course
data) (follow up turning)
Function check of RoT
10
Check the fan, the display and the follow-up.
DO NOT PERFORM DURING THE
HEATING PHASE!!
11
Turn off the follow-up system
(
Service only
)
12
Adjustments to read--out of data.
see following steps.
12
Step 1
Indicate encoder heading