OPERATION
NautoPilot 5000 Series
156
4002.DOC010102
Edition: September 2014
Message
Possible cause
Remedy
Off Heading
----------------------------------------------
Off Heading
A difference between ac-
tual heading and set
heading has been found.
-- Check RAD/RoT
adjustments
(see section 2.3.6.3).
-- Check Rudder
limit adjustments
(see section 2.3.6.4).
-- Check OFF
Heading Limit
adjustments
(see section 2.3.6.4).
-- Check the control
loop for the Heading
control.
Off Track XTD greater
than 0000m
----------------------------------------------
Off Track XTD gr
A difference between ac-
tual track and set track
has been found.
-- Check RAD/RoT
adjustments
(see section 2.3.6.3).
-- Check Rudder limit
adjustments
(see section 2.3.6.4).
-- Check OFF Heading
Limit adjustments
(see section 2.3.6.4).
-- Check the control
loop for the Track
Control.
One Software Package
found.
--------------------------------------
one Software Pac
At connected USB stick a software version was de-
tected.
Operator Unit Failed
----------------------------------------------
OU Failed
A (second) NautoPilot
Operator Unit has failed.
Check NautoPilot
Operator Unit.
Operator Unit not ac-
tive!
Activate now?
----------------------------------------------
Operator Unit not ac-
tive! Activate
Operator has pressed a
control mode button on a
stand--by NautoPilot Op-
erator Unit.
Confirm with “SET” to
activate the NautoPilot
Operator Unit.
Position Monitor
Check Position
----------------------------------------------
Position Monitor
-- Position sensor
transmits invalid
data.
-- Wrong drift
adjustment.
-- Check Drift
adjustment (if only
one position sensor
is installed).
-- Check position
sensor(s)
(see section 2.3.5.5).