OPERATION
AUTOPILOT
NautoPilot 5000 Series
7
4002.DOC010102
Edition: September 2014
1.2
Technical Data
1.2.1
Mechanical Data
For dimensions, type of enclosure and weight see the appended
Dimensional Drawing 102--890.HP005 for Autopilot 102--890.NG001 or
Dimensional Drawing 102--890.HP015 for Autopilot 102--890.NG002.
1.2.2
Electrical Data
Supply voltage (plug B12)
24V DC (18 to 36V DC)
Power consumption
Approx. 25 W
Ambient temperature (operation)
--25
C to +55
C
Ambient temperature (storage)
--40
C to +70
C
Outputs (Status):
-- Status and alarm contacts
(plugs B3, B4, B5 and B6)
Output load 30V DC, Imax. 1A
Inputs (Status):
Status (plugs B10 and B11)
24V DC, Imax. 5mA
Outputs/Inputs:
Serial in/out (plugs B8 and B9)
RS422 (NMEA)
CAN bus (plugs B21 and B22)
according to RAN CAN bus specification
LAN
(ETHERNET)
Signal Inputs:
Gyro Compass, Satellite Compass
Course Bus or NMEA*
Magnetic Compass/Fluxgate
Course Bus or NMEA*
Speed Log
Course Bus or NMEA*
Position Receiver
NMEA*
ECDIS (for Track Control)
according to IEC 62065,
APB NMEA*
*NMEA according to IEC 61162--1, --2
1.2.3
Cable length and diameters
CAN bus
4x2.0x0.75 twisted/screened, max. 400 meters
Status lines
1mm
2
Power lines
1.5mm
2