OPERATION
NautoPilot 5000 Series
60
4002.DOC010102
Edition: September 2014
Function
Figure 28/17 Softkeys for changing selected rudder parameters.
Changes must be acknowledged with ”SET” (a small icon is
displayed after a change has been made, see Figure 29).
Figure 28/18 Softkey for switching back to the previous display, without a
transfer of changed values.
Figure 28/19 Softkey for changing/entering the Track Econ parameter to in-
fluence rudder activity (see section 1.3.8).
Figure 28/20 For “Adaptive mode” only and not for NP 5100.
Softkey for changing/entering the ship load condition
parameter (see also section 1.3.4). Value range: 10% to 100%
(in increments of 10%).
Use the ”+” and”--” softkeys to make a change.
Changes must be acknowledged with ”SET” (a small icon is
displayed after a change has been made,
see Figure 29).
Figure 28/21 Softkey for changing/entering the counter rudder parameter
(see also section 1.3.3). Value range: 0 to 9
(in increments of 1).
Use the ”+” and”--” softkeys to make a change.
Changes must be acknowledged with ”SET” (a small icon is
displayed after a change has been made, see Figure 29).
Figure 28/22 Softkey for changing/entering the rudder parameter (see also
section 1.3.2). Value range: 1 to 9 (in increments of 1).
Use the ”+” and”--” softkeys to make a change.
Changes must be acknowledged with ”SET” (a small icon is
displayed after a change has been made, see Figure 29).
Figure 28/23 Softkey for changing/entering the yawing parameter (see also
section 1.3.1). Value range: 1 to 6 (in increments of 1).
Use the ”+” and”--” softkeys to make a change.
Changes must be acknowledged with ”SET” (a small icon is
displayed after a change has been made, see Figure 29).