OPERATION
NautoPilot 5000 Series
68
4002.DOC010102
Edition: September 2014
Function
Figure 33/17 Softkey for switching an alarm ON or OFF if the acceleration
overshoots an adjusted acceleration limit value (percentage
value).
Possible settings are:
-- Off (no alert)
-- On (an alert is activated if the limit is reached or
exceeded). “Accel. Monitor” is displayed in the status bar
at the top of the display.
Figure 33/18 Softkey for adjusting speed.
Adjusted value influences the ”Acceleration Limit” (indication at
the top of this display).
Value range: 0.0kn to 90.0kn (in increments of 1kn).
Figure 33/19 Softkey for adjusting the Rate of Turn (in degrees) in combina-
tion with the speed.
Adjusted value influences the ”Acceleration Limit” (indication at
the top of this display).
Value range: 5
/min to 500
/min (in increments of 1
/min.)
Figure 33/20 Softkey for adjusting the acceleration limit. This adjustment in-
fluences the Rate of Turn in the display below.
Value range: 0.000m/s
2
to 9.999/m/s
2
(in increments of
0.001m/s
2
).
Please note:
Critical values are displayed with a small attention icon.
These values must be checked and corrected.
Figure 34: Example of a request to press ”SET” after a parameter has been changed