Operator Manual
Raytheon Marine GmbH
Germany
R
NSC 18
RADAR
2
−
43
3748DOC020102
Edition: 14.JAN.2005
2.3.3
Radar video settings
2.3.3.1
Range RNG
Range (RNG) shows the selected range area in NM.
The NSC allows up to 11 range settings.
Selecting the relevant toggle fields switches the range image displayed up or
down.
Range RNG in NM Range ring distance in NM
Range rings RR
0.125
0.0625
2
0.25
0.125
2
0.5
0.25
3
0.75
0.25
3
1.5
0.25
6
3.0
0.5
6
6.0
1.0
6
12.0
2.0
6
24.0
4.0
6
48.0
8.0
6
96.0
16.0
6
Table:2 Overview range, SHM and rings
2.3.3.2
RINGS
The spacing between the rings is defined in the Range Rings (RR) toggle field.
The Range Rings toggle field is also used to turn range rings ON/OFF in the
radar video.
This toggle field automatically shows the distance between the rings in nautical
miles. Activating the toggle field displays the rings in the radar video.